Installation; General Installation; Clearances; Siting - Garland MSTSR16-280 Installation And Operation Manual

Master sentry gas-operated salamander
Table of Contents

Advertisement

INTRODUCTION continued
For proper operation, the Fuel information on the data plate
of you new equipment must match your fuel supply .

INSTALLATION

General Installation

1 . Carefully remove unit from carton . All packing material
must be removed from the unit . The wires for retaining
the burners & other packing material must be removed
from unit . On stainless steel units, the protective
material covering the stainless steel must be removed
immediately after unit is installed .
NOTE: Do not remove permanently affixed labels, warnings
or data plates from the appliance, for this may invalidate the
manufacturer's warranty .
2 . Place the appliance in the required position and level by
means of the levelling feet .
3 . Connect the gas supply pipe work to the appliance . The
connection is made to the rear right hand side of the
appliance .
NOTE: A gas isolation cock must be fitted in the supply
to the appliance . The gas isolation cock must be sited in a
position which is easily accessible to the user .

Clearances

The space in which the appliance is to be sited must include
the minimum installation clearances to combustible surfaces
shown in the following table .
MINIMUM INSTALLATION CLEARANCES
Surface
Top
Left Hand Side
Right Hand Side
Rear
TYPE OF FLOOR OR BASE
Combustible

Part # P143 (11/10/08)

All Models
1219mm (48 in .)
152mm (6 in .)
152mm (6 in .)
152mm (6 in .)

Siting

The unit should be installed on a firm, smooth and level
base capable of adequately supporting the weight of the
appliance and any ancillary equipment . (Refer to table A for
weight specifications) . Any openings in the wall behind or
beside the appliance must be sealed . Once in position check
that the unit is level, both front to back and side to side .
Adjust if necessary using the leveling feet on the four corners
of the fitted legs .

Ventilation Air

The area in which the appliance is installed must be
adequately ventilated to provide air for combustion, removal
of products of combustion, etc . The use of a mechanical
extract system should be considered
The following notes are intended to give general guidance .
For detailed recommendations, refer to the applicable
code(s) in the Country of destination .
1: The room containing the appliance is required to have a
permanent air vent . The minimum effective area of the
vent is related to the maximum rated heat input of the
appliance and shall be 4 .5 cm
2: Air vents should be of such a size to compensate for the
effects of any extract fan in the premises .

Statutory Regulations

The installation of this appliance must be carried out by
a competent person and in accordance with the relevant
regulations, standards, codes of practice and the related
publications of the Country of destination .
AUSTRALIA SPECIFIC CLAUSE This appliance must be
installed in accordance with the manufacturers instructions,
local gas fitting regulations and requirements of AS 5601 /
AG 601 installation code . All burner adjustments and settings
should be made by a qualified gas technician .
per kW in excess of 7 kW .