Garland GAS PIZZA OVENS Installation & Operating Instructions Manual

Gpd series gas pizza ovens

Advertisement

INSTALLATION, OPERATING
& SERVICE INSTRUCTIONS
GARLAND GPD SERIES GAS PIZZA OVENS
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER
FLAMMABLE VAPORS OR LIQUIDS IN THE
VICINITY OF THIS OR ANY OTHER APPLIANCE.
PLEASE READ ALL SECTIONS OF THIS MANUAL AND RETAIN FOR FUTURE REFERENCE.
THIS PRODUCT HAS BEEN CERTIFIED AS COMMERCIAL COOKING EQUIPMENT AND MUST BE INSTALLED
BY PROFESSIONAL PERSONNEL AS SPECIFIED.
IN THE COMMONWEALTH OF MASSACHUSETTS THIS PRODUCT MUST BE INSTALLED BY A LICENSED
PLUMBER OR GAS FITTER. APPROVAL NUMBER: G-1-07-05-28
For Your Safety:
Post in a prominent location, instructions to be followed in the event the user smells gas. This information shall be
obtained by consulting your local gas supplier.
Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent using genuine
Garland replacement parts. Garland will have no obligation with respect to any product that has been improperly installed,
adjusted, operated or not maintained in accordance with national and local codes or installation instructions provided
with the product, or any product that has its serial number defaced, obliterated or removed, or which has been modified
or repaired using unauthorized parts or by unauthorized service agents. For a list of authorized service agents, please refer
to the Garland web site at http://www.garland-group.com. The information contained herein, (including design and parts
specifications), may be superseded and is subject to change without notice.
Continuous product improvement is a Garland policy, therefore design and specifications are subject to change without notice.
GARLAND COMMERCIAL INDUSTRIES
185 East South Street
Freeland, Pennsylvania 18224
Phone: (570) 636-1000
Fax: (570) 636-3903
Part # 1844063 (08/06)
Part # 1844063 (08/06)
FOR THE
ALTERATION, SERVICE OR MAINTENANCE CAN
CAUSE PROPERTY DAMAGE, INJURY OR DEATH.
MAINTENANCE INSTRUCTIONS THOROUGHLY
GARLAND COMMERCIAL RANGES,
LTD.
1177 Kamato Road, Mississauga, Ontario L4W 1X4
CANADA
Phone: 905-624-0260
Fax: 905-624-5669
WARNING:
IMPROPER INSTALLATION, ADJUSTMENT,
READ THE INSTALLATION, OPERATION AND
BEFORE INSTALLING OR SERVICING
THIS EQUIPMENT.
Enodis UK LTD.
Swallowfield Way, Hayes, Middlesex UB3 1DQ ENGLAND
Telephone: 081-561-0433
Fax: 081-848-0041
© 2005 Garland Commercial Industries, Inc.
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Garland GAS PIZZA OVENS

  • Page 1: Service Instructions

    Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent using genuine Garland replacement parts. Garland will have no obligation with respect to any product that has been improperly installed, adjusted, operated or not maintained in accordance with national and local codes or installation instructions provided with the product, or any product that has its serial number defaced, obliterated or removed, or which has been modified...
  • Page 2: Important Information

    IMPORTANT INFORMATION WARNING: This product contains chemicals known to the State of California to cause cancer and/or birth defects or other reproductive harm. Installation and servicing of this product could expose you to airborne particles of glass wool/ ceramic fibers. Inhalation of airborne particles of glass wool/ceramic fibers is known to the State of California to causes cancer.
  • Page 3: Table Of Contents

    Oven Exterior: ......12 Oven Interior: ......12 Core Plates: .
  • Page 4: Gpd Series

    DIMENSIONS AND SPECIFICATIONS GPD SERIES Ratings shown are for natural gas installations up to 2000 feet (610m) above sea level. BTU input ratings must be de-rated for high altitude installations. Specify altitude of product if over 2000 feet (610m) This product is not approved for residential Installation Notes: Non-Combustible &...
  • Page 5: Installation

    Garland/U.S. Range products are not approved or authorized for home or residential use, but are intended for commercial applications only. Garland / U.S. Range will not provide service, warranty, maintenance or support of any kind other than in commercial applications.
  • Page 6: Installation Clearances

    NOTE: When checking pressure be sure that all other equipment on the same gas line is on. A pressure regulator is supplied with GARLAND Pizza Ovens. Regulator is preset to deliver gas at pressure shown on the rating plate.
  • Page 7: Installing Under Ventilation Canopy

    Termination Less than 10 feet (3 meters) from ridge Installing Under Ventilation Canopy: Too strong a pull through the exhaust system will pull heat out of the oven too rapidly and cause uneven baking (strong bottoms and light tops). All ovens, operating under a ventilating canopy should be equipped with a canopy flue diverter assembly (supplied...
  • Page 8: Double Deck Assembly

    (bumps) in the up position. 3. If the oven is supplied with a steel hearth assembly, place the hearth spacers (with the flat side in the up position) on the extreme left and right sides of the oven resting on the heat deflectors.
  • Page 9: Adjustments

    7. A separate shut-off valve for each oven must be provided. It should be as close as possible to the place where the gas line goes into the oven. It must be located so that it is easily accessible. A handle or wrench should be chained to the valve where it will always be at hand.
  • Page 10: By-Pass Flame Adjustment

    This adjustment is best done when the oven is being heated for the day’s business. To adjust the by-pass flame follow steps  thru . 1. Turn the oven on and set the thermostat to the desired temperature.
  • Page 11: Flame Diverters

    flame diverters adversely affect the oven performance. Check them periodically and replace as needed. Make sure that the “V” shaped diverters are pushed all the way to the back of the oven as far as they will go. OPERATION 3.
  • Page 12: Lighting/Shutdown Instructions

    6. When the oven has reached the selected temperature, experiment until you get the feel of the oven and the speed of the bake. In case of some initial unevenness in the baking, have patience for a few days until the...
  • Page 13: Troubleshooting Guide

    Burner flame shuts off when oven reaches set temperature Part # 1844063 (08/06) Causes Flame diverters not installed properly Push all the way to the back of oven Flame diverters warped or damaged Deposit on deck Low production oven idling By-pass flame too high...
  • Page 14 NOTES Page 14 Part # 1844063 (08/06)
  • Page 15 (07/05) 1844063 nº Pièce dérivation amme fl taille pression correct orifi Remplacer pression d’air l’obturateur (régler) pression d’air l’obturateur (régler) ensuite l’abaisser lacuisson pour température Augmenter d’obturateur volet correctement préchauffer four pâte fraîcheur température Augmenter cuisson Prolonger d’entretien technicien appelerun réelle;...
  • Page 16 Page grattoir. d’un peuvent tenaces résidus dure. retirer à faciles carbonisés seront four, refroidissement Après cycle accomplir thermostat journée fi à degrés thermostat régler sole, plaques garantie. annule sole refroidir pour d’eau L’utilisation ménager détergent humide nettoyées être doivent aluminisé ».
  • Page 17 (07/05) 1844063 nº Pièce sèche. jusqu’à jours quelques d’attendre faut apparaissent, cuisson inégalités cuisson. vitesses four pour pratiques expériences sélectionnée, température atteint 1/2. pendant sélectionnée température chauff four Laisser degrés marque vers thermostat protection. couche fi four l’intérieur proviennent émanations fumée émanations toutes...
  • Page 18 Page elles. pour conçus letés dans remonter vis, dégagement extrémités avec contact d’étalonnage blocage réglage ectuer d’eff possible place. bouton bien plaque Maintenir l’indicateur. à conforme soit thermomètre à façon d’étalonnage plaque commande. indépendamment bouger puisse qu’on jusqu’à d’étalonnage desserrer d’étalonnage plaque réglage.
  • Page 19 (07/05) 1844063 nº Pièce amme fl couleur bonne disque reculer cas, tels Dans dans d’air quantité indiquer compartiment dans four suie besoin. mélange réajuster amme fl périodiquement vérifi four, d’autres carbone dépôts brûleurs orifi nettoyer métallique fi l d’un l’aide à...
  • Page 20 Page 90° FEMELLE UNION 90° FEMELLE FILETÉ 90° FEMELLE four. chaque pour soit d’arrêt, d’installer convient superposés, moment. tout à disponible enchaînée être doit clef accessible. facilement être devra canalisation d’entrée l’endroit près aussi placé être devra séparé d’arrêt robinet d’installer propane.
  • Page 21 (07/05) 1844063 nº Pièce partie d’évent trou s’insère inférieure section s’assurant bois pièce doucement inférieure. placer four supérieure section fumée. conduits éviter pour l’appareil arrière supérieure travers 1650 bois pièce longue enlevé. été encore arrière inférieure partie à d’évent Retirer supérieure.
  • Page 22 Page rainure mètres) Min. (90cm) Pieds Mètres) Pieds COUPE-TIRAGE fumée conduit dans d’acier d’obturation volet installer cas, conçu. bien cheminée chapeau doit avoisinante haute plus structure (m) pieds  à four, d’installation toit au-dessus (m) pieds  doit adéquate taille métallique branchement possible...
  • Page 23 Alimentation système d’un partie pression installée hotte GARLAND.   régulateur dimensions même constitué s’assurer l’appareil. ventilation dépassant satisfaisante alimenter équipements compteur être doit appareil Ventilation nécessaire »...
  • Page 24 Range U.S. Garland seulement. applications à destinés sont personnelle utilisation pour autorisés sont Range Garland/U.S. produits professionnel personnel installé service département avec...
  • Page 25 (07/05) 1844063 nº Pièce (1149) 45-1/4 (1588) 62-1/2 (1149) 45-1/4 (1588) 62-1/2 (1149) 45-1/4 (1340) 52-3/4 (1149) 45-1/4 (1340) 52-3/4 pieds) (avec (mm) Extérieures [203mm] 8" [318mm] 12-1/2" [1149mm] 45-1/4" [201mm] 7-15/16" [76mm] 3" [195mm] 7-21/32" PONT [1143mm] 45" [1346mm] 53"...
  • Page 26 Page Dépannage Four D’arrêt D’allumage Ventilation Guide sole Plaques four Intérieur Extérieur Nettoyage Instructions Rodage Fonctionnement MATIÈRES TABLE (07/05) 1844063 Flammes ecteurs Étalonnage Dérivation: Flamme D’air Mélange Flamme pression Gaz: Branchement Sections Deux À Four Assemblage Sole Installation Pieds Installation D’assemblage Instructions Directe...
  • Page 27 (07/05) 1844063 nº Pièce Éloigné Dégagé reproducteur. l’appareil à dommages l’État dans connue carbone inhaler à l’utilisateur exposer l’État dans connue l’air dans l’air. dans suspension céramiques l’entretien L’installation et/ou cancer causant comme IMPORTANTES Combustible! Produit L’appareil Autour autres congénitales anomalies d’oxyde L’inhalation...
  • Page 28 Inc. Industries, Commercial Garland 2005 Page 081-848-0041 Télécopieur 081-561-0433 Téléphone ANGLETERRE Middlesex Hayes, Way, Swallowfi LTD. Enodis préavis. sans ées modifi être peuvent cations spécifi peuvent pièces) cations spécifi http://www.garland-group. à : Garland d’entretien agents autorisées mutilé, été aurait série numéro...

This manual is also suitable for:

Gpd48Gpd60Gpd48-2Gpd60-2

Table of Contents