WAR NIN6S
Models: G2250S
&G3250S
This owner's manual is considered a permanent part ofthe generator
and should remain with the generator if resold. The information and
specifications included inthis publication were in effect atthe time of
approval for printing.
GXi Outdoor Power, LLC,reserves the right to discontinue or change
specifications or design at any time without notice and without incur-
ring any obligation whatever. No part of this publication may be repro-
duced without written permission.
EMISSION CONTROLSYSTEM INFORMATION
The U.S.and California Clean Air Acts
EPAand California regulations require all manufacturers to furnish
written instructions describing the operation and maintenance of emis-
sion control systems. The following instructions and procedures must
be followed in order to keepthe emissions from your STANLEYengine
within the emission standards. Maintenance, replacement, or repair of
the emission control devices and systems may be performed by any
engine repair establishment or individual, using parts that are
"certified" to EPAstandards.
SAFETY LABEL LOCATIONS
These labels warn you of potential hazards that can cause serious
injury. Readthem carefully. If a label comes off or becomes hard to
read, contact your STANLEYgenerator dealer for a replacement.
SAFETY INFORMATION
STANLEYgenerators are designed to give safe and dependable
service if operated according to instructions. Read and under-
stand this owner's manual before operating your generator.
OPERATORRESPONSIBILITY
Know howto stop the generator quickly in case of emergency. Under-
stand the use of all generator controls, output receptacles, and con-
nections. Be sure that anyone who operates the generator receives
proper instruction. Donot let children operate the generator.
The engine exhaust from this product contains chemicals known to
the State of California to cause cancer, birth defects or other re-
productive harm.
CARBON MONOXIDE GAS
Exhaust contains poisonous carbon monoxide, a colorless and
odorless gas. Breathing exhaust can cause loss of consciousness
and may lead to death. To keep exhaust gas from accumulating,
use in an area with adequate ventilation.
DO NOT use this genera-
tor in a garage, basement, crawlspace, enclosed shed, or any
other area that does not have adequate ventilation.
DO NOT use
this generator near ventilation ducts or open windows that may
allow exhaust gasses to enter your home or business.
ONLY
operate this generator
outdoors.
Fire and Burn Hazards
The exhaust system gets hot enough to ignite some materials.
Keep the generator at least 3 feet (1 meter) away from buildings
and other equipment during operation.
Do not enclose the generator in any structure.
Do not smoke when refueling.
Keep flammable materials away from the generator.
The muffler becomes very hot during operation and remains hot for
a while after stopping the engine. Be careful not to touch the muf-
fler while it is hot.
Let the engine cool before storing the generator indoors.
Refuel in a well ventilated area with the engine stopped.
Fuelvapors are extremely flammable and may ignite after the en-
gine has started. Make sure that any spilled fuel has been wiped
up before starting the generator.
Electocution
hazard - Electricity can cause DEATH or SERIOUS
INJURY.
Do not operate the generator when moisture is present.
This product is not safe to operate in the presence of water or
nearwater.
Properly ground the generator and verify ground is in place
before each use. Grounding regulations vary by location, con-
sult a qualified local electrician for proper grounding instruc-
tions.
Power cords and electrical equipment pose a risk of shock and
electrocution, especially if they are operated in wet conditions.
Inspect all equipment prior to every use and use only as di-
rected by the manufacturer.
Use a cord with GFCI protection when using the power out-
doors or when moisture is present.
Generators vibrate in normal use. During and after the use of
the generator, inspect the generator as well as extension cords
and power supply cords connected to it for damage resulting
from vibration. Have damaged items repaired or replaced as
necessary. Do not use plugs or cords that show signs of dam-
age such as broken or cracked insulation or damaged blades.
Do not connectthis
generator to a building electrical system.
Improper connections to a building electrical system can allow
electrical current from the generator to backfeed into the utility
lines. Such backfeed may electrocute utility company workers or
others who contact the lines during a power outage, and the gen-
erator may explode, burn, or cause fires when utility power is re-
sto red.
Ground System
STANLEYportable generators have a system ground that connects gen-
erator frame components to the ground terminals in the AC output re-
ceptacles. The system ground is connected to the AC neutral wire.
Special Requirements
There may be Federal or State Occupational Safety and Health Admini-
stration (OSHA) regulations, local codes, or ordinances that apply to the
intended use ofthe generator. Please consult a qualified electrician,
electrical inspector, orthe local agency having jurisdiction.
This generator does not meet US Coast Guard regulation 33 CFR-183
and should not be used on marine applications.
NEVERSTARTORSTOPTHE ENGINEWITH DEVICESCON-
NECTED TOTHE GENERATOR.
Rev. 7/2010
STANLEY is a registered trademark of The Stanley Works or its affiliates and are used under license by GXi Outdoor Power LLC.
No part of this publication can be printed or copied without written permission.