BURN ONLY #2FUEL OILINTHIS APPLIANCE.
DO
NOT USE GASOLINE,
CRANKCASE
DRAININGS
OR
ANY OILCONTAINING
GASOLINE.
V;.
:{IJ ;| tH =1;!1 hH--'_l€;_ II W;'I / [e] L_
I
The oil burner is supplied with a mounting
flange
fixed in position.
2. BE SURE HI TEMP GASKET IS BETWEEN THE
BURNER MOUNTING
FLANGE AND THE
COMBUSTION
CHAMBER COVER PLATE.
3.
Care must be taken when routing the oil lines so not
to interfere with the opening and closing of the
burner mounting
plate. Flexible oil lines or flared
copper disconnects
with valves (when copper lines
are used) may be installed to assure full opening of
the burner mounting plate when servicing.
4.
Oil Burner Specifications:
For information
pertinent to the oil burner such as
nozzle sizing, fuel supply piping, adjusting or
servicing, refer to the charts below and the burner
installation
manual
5.
Sampling tapping in CeraFlex Appliance Adapter
must be used for COz, smoke and flue pressure
readings.
6.
Burner should start automatically
when thermostat
is
turned up and main boiler service switch is turned
on. If burner does not start, check to be sure there is
oil in the tank and push reset button on burner
control: (Beckett) square red button; (Riello) round
red button inside clear flexible cover on back of
burner coven If burner still does not start, contact
serviceman.
Do not attempt to start the burner when excess oil
has accumulated, when the unit is full of vapor, or
when the combustion
chamber is very hot.
7. Burner and boiler can be shut down by turning down
the thermostat
and moving the main boiler service
switch to the "off" position.
Always keep the manual fuel supply valve shut off
if the burner is shut down for an extended period
of time.
Table
2
Boiler Model No.
WV-DV-03-075
WV-DV-03-085
WV-DV-03-110
Riello BF5 Oil Burner
Delavan Nozzle
Pump Pressure
Size
(psig)
.60 80 ° B
165
.65 80 ° B
165
.90 80 ° B
165
Turbulator
Setting
1
1
2
Air Damper
Setting
3.3
3.8
5.0
Table 3
Boiler Model
No.
WV-DV-03-075
WV-DV-03-085
WV-DV-03-110
Beckett AFII 100 Burner
Nozzle
Pump Pressure
Manufacturer,
Size
(psig)
Delavan .60 70 ° B
170
Hago .65 45 ° B
170
Delavan .85 60 ° B
170
Pin No.
3
4
6
Air Dial
Setting
4.25
5.5
6.5
Start-up and adjustment recommendations: Above Turbu[ator, Pin, Air Damper, and Air Dial settings are start-up settings
only. Adjust burner for highest CO2 (no more than ]3%) while maintaining
a 0 smoke spot. Pressure or draft over fire and in
flue cannot be adjusted. HoweveT, draft and/or presstlre measurements must be taken in these two [oec3t[onsand recorded
for reference. AI_ adjustments and measurements must be made using suitable instruments such as those found in a
Bacharaeh Combustion Test Kit