5
1" 31/32 (50 mm)
To ensure internal ventilation, aeration
channels must be provided as illustrated
in the figures 5.4 and 5.5.
The walls surrounding the oven must
be made of heat-resistant material.
Taking care NOT to lift the oven by the
door handle.
23" 5/8 min (600 mm min)
1" 11/64 (30 mm)
1" 31/32 (50 mm)
21" 21/32 (550 mm)
Fig. 5.4
Fig. 5.5
IMPORTANT:
To avoid damage to the lower trim
please note the following instructions.
The lower trim is designed to allow for
good air circulation and the correct open-
ing of the oven door.
To ensure the trim is not damaged due to
the appliance being placed on the floor,
the appliance should be suitably sup-
ported as in above illustrations.
OVEN DOOR
After installation the appliance door
should be slowly opened to ensure no
damage has occurred.
LOWER TRIM
No responsibility for lower trim dam-
AIR FLOW
age will be accepted if these instruc-
tions have not been followed.
Fig. 5.6