Fisher & Paykel FREESTANDING COOKER OR120 User Manual page 14

Freestanding cooker double oven models
Hide thumbs Also See for FREESTANDING COOKER OR120:
Table of Contents

Advertisement

Installation instructions
12
Connecting the feeder cable
To connect the feeder cable to the cooker:
Remove the four screws that hold shield "A"
behind the cooker.
Open the cable clamp "D" completely.
Check the position of the U bolts on the
terminal block "B" (Fig. 7a) according to the
diagram in Fig. 7b and Fig. 7c.
Insert the feeder cable into the cable clamp
"D" and into the cable protector "C". The
supply cable must be of a suitable size for
the current requirements of the appliance;
see 'Feeder cable section' following.
Connect the phase and earth cables to
terminal "B" according to Figs. 7b and 7c.
Pull the feeder cable and block it with the
cable clamp "D".
Re-mount shield "A".
Note: the earth conductor must be left
about 30 mm longer than the others.
Feeder cable section
"TYPE H05RR-F"
230V
3 x 2.5 mm
(**)
- Connection with wall
box connection.
2
(**)
B
C
D
1
2
3
4
5
L1
N(L2)
Red or
Red or
Brown
Brown
(Live)
(Live)
Black
Black or
Blue
or Blue
(Neutral)
(Neutral)
230 V
1 2 3 4 5
L
N (L
)
1
2
PE
N
L
A
Fig. 7a
PE
Green
Green
and
and
Yellow
Yellow
(Earth)
(Earth)
Fig. 7b
PE
Earth
Neutral
Live
Fig. 7c

Advertisement

Table of Contents
loading

Table of Contents

Save PDF