Section 3-1-2: Venting Components
The following venting components and associated Montigo
part numbers are available for the EDVRSPV58:
A - Termination
EDVRSPV58
B - Rough-in Frame
EDVRSPV58F
C - Flex Sections
PFL-1 (12" Section)
PFL-2 (24" Section)
PFL-3 (36" Section)
PFL-4 (48" Section)
D - Rigid Sections
PEXT - 1 (12" m/f Section)
PXT-20 (20" section)
PEXT - 2 (24" m/f Section)
PEXT - 3 (36" m/f Section)
PEXT - 4 (48" m/f Section)
E - Elbows
PEL-90MM (m/m 90° Elbow)
PEL-90FF (f/f 90° Elbow)
PEL-90FM (f/m 90° Elbow)
PEL-45FM (f/m 45° Elbow)
F - Power Cord
EPVH10 -10 foot power cord and harness
Harnesses:
EPVH20 -20 foot power cord and harness
EPVH30 -30 foot power cord and harness
EPVH40 -40 foot power cord and harness
EPVH50 -50 foot power cord and harness
EPVH60 -60 foot power cord and harness
EPVH70 -70 foot power cord and harness
EPVH80 -80 foot power cord and harness
EPVH90 -90 foot power cord and harness
EPVH100 -100 foot power cord and harness
Connection and installation of the vent components
should adhere to the following guidelines:
■ Connect all vent sections using a minimum of three
sheet metal screws on the outer pipe flue.
■ Ensure the pipe ends male to female slide in a
minimum of 1 1/2" of overlap.
■ Ensure all runs are supported with a minimum of
3 supports per 10' of venting.
■ When hanging/ supporting venting, ensure that
1" clearance is maintained on all sides to any
combustible material.
■ Ensure when cutting sections of rigid pipe to maintain
integrity of internal supports.
■ Place the springs, supplied with the pipe kit, between
the outer and inner pipes to keep the pipes separate
and avoid any possible hot spots.
■ Montigo recommends the use of a flex section for the
final pipe connected directly to the fireplace offering
greater flexibility of installation and absorption of
movement.
■ All exterior joints in venting should be sealed with
high heat silicone RV230.
Page 10
Installation
Section 3-1-3: Installation of the EDVRSPV58
External roof mounted power vent module.
Refer to Appendix A - Power Vent locations, to ensure the
planned Vertical Power vent location is acceptable.
The EDVRSPV58 Power Vent dimensions:
The EDVRSPV58F Rough-in Frame dimensions:
Ø14"
2"
Ø 1/2"
Front View
18"
18"
Top View
6"
Ø 8"
14"
Front View
18"
18"
Top View
19 1/4"
8 1/2"
XG0770 - 020911