Danger of harming radiation Environment your hands Gas bottles Watch for Electricity Danger for cutter Entrapment hazard Battery hazard Rotating parts falling objects ® XG0773 150127 Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248...
R520-ST & R620-ST Power Vent Indoor Gas Fireplace Table of Contents Instruction Manual Contents Section 7: Testing the system Introduction 7-1: Testing the system before gas connection Safety Alerts 7-2: Testing the system with gas connection Pre-Installation Checklist Mantels & Surrounds Understanding the Basic Operation of the Residential R520-ST &...
Congratulations on your purchase of a Montigo Warranty and Installation Information: (See Appendix Fireplace. The Montigo warranty will be voided by, and Montigo disclaims any responsibility for, the following actions: With over 30 years of experience, Montigo is committed to providing you with a gas fireplace that is not only a beautiful ►...
■ Refer to the Section 4 on Page 10, "Installing the Power Vent" for details. ■ Montigo supplies 20' of low voltage wire, which can be spliced Installation and repairs should be done by an authorized gas fireplace service technician.
To operate the fireplace, Montigo supplies 20' of low voltage wire from the electrical control panel. Connect the two wire harnesses to a standard single pole ON/OFF switch to the location of your choice.
Back -frame in the fireplace using typical framing practice, see Figure 2 on both sides and meeting clearance requirements shown on page 5. Install the non-combustible headers supplied by Montigo above the fireplace on both sides as required to attach facing. For cleanest finish ensure that the facing material is installed flush to the glass viewing area.
Page 10
Step 4. Installation of the RHS 102 heat shield (See "Figure 7 Sec.4 on page 15"). When the vent passes through the first adjacent ceiling (or wall for horizontal runs) a Montigo RHS102 heat shield must be installed around the pipe as shown above.
Top of fireplace installation of screens. Non-combustible headers supplied by Montigo (may be placed where required for fastening facing) 12 11 10 9 8 7 6 5 4 3 2 1 Glass Figure 1 Sec.3 Combustible mantles and facings. (Not to scale)
Multi-elbow installations are possible up to a maximum of six 90° elbows. Montigo supplies a variety of power venting options. The location of the power vent should be selected and laid out to provide the shortest possible run to an external wall or through the roof.
■ Montigo recommends the use of a flex section for the final pipe connected directly to the fireplace offering greater flexibility of installation and absorption of movement.
R520-ST & R620-ST Power Vent Indoor Gas Fireplace Installation Multi-Elbow Installations Section 4-2: Installing a Wall Mounted Horizontal ExteriorPowerVent Multi-elbow installations are possible up to a maximum of six at 90° elbows. Thissectionappliestoinstallationswheretheshortestpossible Elbow 6 vent run is through an exterior wall. Refer to Appendix A - PowerVentlocations, to ensure the planned Power vent location is acceptable.
■ Montigo recommends the use of a flex section for the final pipe connected directly to the fireplace offering greater flexibility of installation and absorption of movement.
R520-ST & R620-ST Power Vent Indoor Gas Fireplace Installation Section 5: Wiring Installing the Fireplace Control Box Install the Fireplace Control Box in an accessible location. The location should be where maintenance, adjustments and service may be made easily. Vertical Power Vent Termination Power cable Installatio n...
White) to these two wires at a location of your choice, (See Installing the Remote Switch). Figure 3 Sec.5 R520ST / R620ST Control Module Montigo supplies 20' of low voltage wire to the electrical control panel. Connect the two wire harnesses to a standard single pole ON/OFF Installing the Remote Switch switch to the location of your choice.
Page 18
R520-ST & R620-ST Power Vent Indoor Gas Fireplace Installation ELECTRICAL CONTROL PANEL Flue Fuse Wall Combustion Switch R1 R2 R3 Pre-Purge Timer 110 Volts 60Hz Light Plug White PV Speed Controller Black Post Purge Timer White Blue Yellow Wall If any of the original wire supplied with the appliance is Note: Switch replaced, it must be with the same or its equivalent.
To check pressures, control valves have a provision to remove a 1/8” N.PT. plug to be fitted with a hose barb. Montigo requires a service shut off valve be located in an accessible location to isolate the gas supply. Only install gas shut-off valves approved for use by the state, province, or other governing body in which the fireplace is being installed.
R520-ST & R620-ST Power Vent Indoor Gas Fireplace Installation Section 7: Testing the system 7-1: Testing the system before gas connection Note: No gas is needed to test the system The R520ST*/R620ST* Control and Power Vent System can be safely tested prior to finish framing the Fireplace. This test can be done quickly and efficiently to ensure all systems function according to the design specifications.
R520-ST & R620-ST Power Vent Indoor Gas Fireplace Installation Mantels & Surrounds NOTE: National Canadian Gas Association mantel test requirements are for fire hazard prevention to combustible materials. New technology, to meet consumer and government demands for the wise use of energy, has prompted us to manufacture many models of fireplaces which are hot, fuel and energy efficient.
R520-ST & R620-ST Power Vent Indoor Gas Fireplace Installation Section8:Removing&InstallingScreenandWindow Step 2: Lift out Window from Grooves Removing the Screen: The window is removed by first lifting upward on the glass and then Follow the steps below to remove, or install the R520ST* / R620ST* by pulling the bottom out from the groove in which it was located (see image below).
These may be spaced at random, or section. Follow these instructions to ensure all parts are removed or in a visual pattern of your preference. See the Montigo web site for replaced as required. Once the trim and glass door is removed, place photographs and ideas.
R520-ST & R620-ST Power Vent Indoor Gas Fireplace Operation Section10:Start-upSequence FOR YOUR SAFETY - READ BEFORE LIGHTING : LIGHTING INSTRUCTIONS: TO TURN OFF GAS TO APPLIANCE: Page 24 XG0773 - 150127...
R520-ST & R620-ST Power Vent Indoor Gas Fireplace Maintenance Section 11: Cleaning and Maintenance See Lighting Instructions section. Cleaning General When the fireplace is first activated, there may be some smoking and ■ Havethefireplaceandinstallationinspectedyearly. The a visible film may be left on the glass. This is a normal condition, and inspection must include, but is not limited to, the following: is the result of burning of protective coatings on new metal.
R520-ST & R620-ST Power Vent Indoor Gas Fireplace Maintenance Replacement Parts Honeywell HSI R520-ST R620-ST RGC1004 NG Gas Valve RGC1003 LP Gas Valve RPA003-30 NG Pilot Assembly RPA004-30 LP Pilot Assembly RESCB2 Power Vent Control Box RGL1065 RGL1066 Outer Glass RSCR520 RSCR620 Replacement Screen...
R520-ST & R620-ST Power Vent Indoor Gas Fireplace Appendix AppendixA:PowerVentLocations PV VEX510-300 Vertical Power Vent Detail Not Acceptable For installation instructions on this termination see instruction guide for the PVVEX510-300. FrontView Figure 1 Appendix PVVEX510-300 SideView Wall [610 mm] Figure 3 Appendix PVVEX510-300 restrictions 24”...
R520-ST & R620-ST Power Vent Indoor Gas Fireplace Appendix PVVEX510-300 Power Vent Locations PVVEX58 300 V VENTER TERMINAL X AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED Canadian Installations US Installations Canadian Installations US Installations A= Clearance above grade, veranda, 12 in (30 cm) 12 in (30 cm) J= Clearance to nonmechanical air...
R520-ST & R620-ST Power Vent Indoor Gas Fireplace Appendix PVHEX510-300 Horizontal Power Vent Detail For installation instructions on this termination see instruction guide for the PVHEX510-300. Figure 5 Appendix PVHEX510-300 Eaves / Overhang 6” 14” [152mm] [355mm] Wal l 6” [152mm] 32”...
R520-ST & R620-ST Power Vent Indoor Gas Fireplace Appendix PVHEX58-300 PVHEX510-300 Power Vent Locations V VENTER TERMINAL X AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED Canadian Installations US Installations Canadian Installations US Installations A= Clearance above grade, veranda, 12 in (30 cm) 12 in (30 cm) J= Clearance to nonmechanical air...
R520-ST & R620-ST Power Vent Indoor Gas Fireplace Appendix PV HFL510-300 Horizontal Power Vent Detail For installation instructions on this termination see instruction guide for the PVHFL510-300. Figure 8 Appendix PVHFL510-300 Eaves / Overhang 15” [152mm] 24” [610mm] Wall 15” [152mm] 24”...
R520-ST & R620-ST Power Vent Indoor Gas Fireplace Appendix PVHFL510-300 Power Vent Locations PVHEX58-300 V VENTER TERMINAL X AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED Canadian Installations US Installations Canadian Installations US Installations A= Clearance above grade, veranda, 12 in (30 cm) 12 in (30 cm) J= Clearance to nonmechanical air...
The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you.
R520-ST & R620-ST Power Vent Indoor Gas Fireplace Appendix AppendixC:StateofMassachusetts Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as follows: Existing chimneys shall be permitted to have their use continued when a gas conversion burner is installed, and shall be equipped with a manually reset device that will automatically shut off the gas to the burner in the event of a sustained back-draft (2) Revise 10.8.3 by adding the following additional requirements:...
Page 35
R520ST & R620ST Power Vent Indoor Gas Fireplace Notes Page 35 XG0773 - 150127...