Section 10: Cleaning and Maintenance
Lighting Instructions See pages 24

General

Have the fireplace and installation inspected yearly.
The inspection must include, but is not limited to, the
following:
• A visual check of the entire vent system and
termination.
• An inspection of the explosion relief flappers and
the door gaskets to ensure a proper seal.
• An inspection of the burner, vent run, and primary
air openings.
• An inspection of the gas valve, gas components, and
pilot flame. For your convenience a 1/8" manifold
pressure tap is supplied on the gas valve for a test
gauge connection.
• Ensure proper log placement as per this manual.
• Inspection of all optional equipment; fans,
thermostats, etc.
For Natural Gas this appliance requires a minimum
inlet pressure of 5.5" W.C. and a manifold pressure of
3.5" W.C.
For Propane Gas this appliance requires a minimum
inlet pressure of 11" W.C. and a manifold pressure of
10" W.C.
Always keep the fireplace area clear and free of
combustible materials, as well as gasoline and other
flammable vapors and liquids.
Do not use this appliance if any part has been under
water. Immediately call a qualified service technician
to inspect the appliance and to replace any part of the
control system and any gas control which has been
under water.

Cleaning

When the fireplace is first activated, there may be some
smoking and a visible film may be left on the glass. This is
a normal condition, and is the result of burning of protective
coatings on new metal.
Glass must be cleaned periodically to remove any film
(which is a normal by-product of combustion) which may
XW2000
Page 24
Maintenance
NOTICE
Do not use ammonia based or abrasive
cleaners on the glass, they will
permanently etch the surface. Use an
approved gas fireplace glass cleaner
such as Kel-Kem or White off.
be visible. Film can easily be removed by removing the
door, as shown on Page 22. Handle the door carefully, and
clean it with non-abrasive glass cleaners. One of the most
effective products is Kel Kem.
Silicone seals on inner door during initial firing will
"off gas", leaving a visual deposit of a white substance on
combustion chamber walls. This can easily be removed
using normal household products.
Use a vacuum cleaner or whisk broom to keep the
control compartment, burner, and firebox free from dust
and lint.

Gas Control Valve

Honeywell (Q3450)
Pilot Assembly
Gas Control
Connector
Figure 32. Gas valve.
Pilot Electrical
Harness Connector
Honeywell Gas
Control (SV9501M)
R
W
Bk
XG0770 - 020911