Specifications - La Crosse Technology WS-450B Owner's Manual

Long range wireless color weather station
Table of Contents

Advertisement

SPECIFICATIONS

Indoor Temperature
In/Out Humidity
Remote sensor
Channel
Transmission
Resolution
Heat Index
Indoor
Outdoor
Elevation
Clock
Power
Trouble shooting for WS 450
Batteries are our #1 warranty issue. Please be sure you are using plain alkaline batteries
dated at least 6 years in advance or reading at least 1.48 on a voltmeter. Be sure that your a/c
cord is properly plugged into the base.
Outdoor Temperature/Humidity
Shows dashes or is inaccurate-
Check placement of sensor and obstructions such as windows, stucco, metal, trees etc.
Did sensor get wet? Bring in, remove, batteries allow to dry and try restart.
The sensor will read the temperature in the location where it is placed. Check for sources
of heat or reflected heat. Position your sensor under an eave or window ledge etc. on
North side of home.
Check the channel button to be sure you are reading the correct sensor.
Please note the humidity range is 20-99%. Below 20% you may see dashes.
Check Batteries-and complete a restart.
Adjust to Fahrenheit or Celsius
On the sensor, remove the battery cover and press the button for F/C
On the base station press the button for F/C
Restart
Bring both units inside and have the units at least 5 feet apart with nothing between them.
Remove all power from both units.
Press one of the buttons on the display at least 20 times to clear all memory. Verify that
the display is blank before proceeding.
Let the all units sit with batteries out for 10 minutes.
Be sure to use a new, Brand Name Alkaline battery dated at least 6 years in advance
(super, ultra, max, heavy duty and rechargeable types should be avoided).
Plug in a/c cord and/or insert batteries in the display unit, then Insert batteries into the
sensor.
Press and hold CHANNEL button on display unit until a beep is sound to search for
remote sensor.
Press the TX button on the back of remote sensor to transmit RF signal.
When RF connection is established, the respective temperature & humidity of the selected
channel will appear on the main unit.
W177.indd 6
: +32 °F to +122 °F (0 °C to + 50 °C)
: 20% - 99% H
: -4 °F to +140 °F (-20 °C to +60 °C)
: max. 3 remote sensors
: up to 75M (246 ft.) in open area, RF434 MHz
: 0.1 degree C for temperature, 1% for humidity
:
: 23°F to 122°F (-5°C to 50°C)
: -4F to 140°F (-20C to 60°C)
: -160 ft. to 3,940 ft. (-50M to 1,200M)
: WWVB Atomic Clock, Quartz back-up
: 6.0V adapter & AAA x 3 pcs for main unit
AAA x 2 pcs for remote sensor
6
9/15/07 10:21:37 AM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ws-450wWs 450