Summary of Contents for FieldServer FS-8700-03 DF1
Page 1
Driver Manual (Supplement to the FieldServer Instruction Manual) FS-8700-03 DF1 APPLICABILITY & EFFECTIVITY Effective for all systems manufactured after December 2011 A Sierra Monitor Company Driver Version: 1.02 Document Revision:...
FS-8700-03 DF1 Driver Manual ALLEN BRADLEY DF1 DESCRIPTION The DF1 driver allows the FieldServer to transfer data to and from devices over RS-232 using DF1 protocol. The FieldServer can emulate either a Server or Client. The information that follows describes how to expand upon the factory defaults provided in the configuration files included with the FieldServer.
This section documents and describes the parameters necessary for configuring the FieldServer to communicate with a DF1 Server The configuration file tells the FieldServer about its interfaces, and the routing of data required. In order to enable the FieldServer for DH+ communications, the driver independent FieldServer buffers need to be declared in the “Data Arrays”...
Not all ports shown are necessarily supported by the hardware. Consult the appropriate Instruction manual for details of the ports available on specific hardware. FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com Legal Values Up to 32 alphanumeric characters...
Not all PLC’s can support all File_Types. Refer to DFS for further information. FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com Page 8 of 16...
This section documents and describes the parameters necessary for configuring the FieldServer to communicate with a DF1 Client. The configuration file tells the FieldServer about its interfaces, and the routing of data required. In order to enable the FieldServer for DF1 communications, the driver independent FieldServer buffers need to be declared in the “Data Arrays”...
Not all PLC’s can support all File_Types. Refer to DFS for further information. FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com Page 12 of 16 Legal Values One of the node names specified in Section 6.2...
Server map 1: N21: 0-31 Server map 2: N21: 32-100 This will panic the FieldServer and crash RS view as the DH+ will attempt to map N21: 0-100. If set up as Server Map 1: N21: 0-100, no problems are experienced.