FieldServer Profibus FS-8700-113 Driver Manual

Fieldserver technologies computer driver instruction manual
Hide thumbs Also See for Profibus FS-8700-113:

Advertisement

Quick Links

(Supplement to the FieldServer Instruction Manual)
APPLICABILITY & EFFECTIVITY
Effective for all systems manufactured after October 2011
Driver Manual
FS-8700-113
X30 Profibus DP Slave)
A Sierra Monitor Company
Driver Version:
1.01
Document Revision:
1

Advertisement

Table of Contents
loading

Summary of Contents for FieldServer Profibus FS-8700-113

  • Page 1 Driver Manual (Supplement to the FieldServer Instruction Manual) FS-8700-113 X30 Profibus DP Slave) APPLICABILITY & EFFECTIVITY Effective for all systems manufactured after October 2011 A Sierra Monitor Company Driver Version: 1.01 Document Revision:...
  • Page 2: Table Of Contents

    Appendix C.1. Using the Siemens PLC with the Anybus Card ... 14 FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com Party Equipment ... 3...
  • Page 3: Profibus X30 Dp Slave Description

    PROFIBUS X30 DP SLAVE DESCRIPTION The FieldServer Profibus DP Slave driver can be used to emulate a single Slave station on a Profibus network. DP Masters can open a connection of up to 244 Bytes of Input and 244 Bytes of Output data, but not exceeding a combined total of 416 Bytes to the FieldServer.
  • Page 4: Hardware Connections

    FS-8700-113 X30 Profibus DP Slave Driver Manual HARDWARE CONNECTIONS The FieldServer is connected to the Profibus network and NetTool as shown in the connection drawing below. Profibus DB9 connector HMS Anybus NetTool RS-232 Serial Cable Profibus DB9 Connector Pinouts Name...
  • Page 5: Data Array Parameters

    , Bit DA_DO_01 , Bit FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com Legal Values Up to 15 alphanumeric characters FLOAT, Packed_Bit, Byte, Packed_Byte,...
  • Page 6: Configuring The Fieldserver As A Profibus Dp Server

    , System_Station_Address Profibus DP The Profibus Station Address can also be set via the two rotary switches on the side of the FieldServer in which case the System_Station_Address setting must be omitted from the configuration file. The settings specified in the configuration file will override the settings on these switches.
  • Page 7: Server Side Connection Parameters

    The X30 Profibus card auto-senses the Baud rate FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com Legal Values Up to 32 alphanumeric characters...
  • Page 8: Server Side Map Descriptor Parameters

    The combined total length of all Map Descriptors may not exceed 416 bytes. FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com Page 8 of 14...
  • Page 9: 5.4.3 Map Descriptor Example

    Input_Data Data Array. FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com Page 9 of 14 , Data_Array_Offset , Function...
  • Page 10: Appendix A. Useful Features

    2 Hz Diagnostics 4 Hz FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com Slave Online Status Slave Offline Status Description Slave is online on the Profibus network...
  • Page 11: Appendix A.2. Setting The Fieldserver's Profibus Station Address

    Appendix A.2. Setting the FieldServer’s Profibus Station Address The Station Address can be set in the FieldServer’s CSV file using the System_Station_Address, (refer to Section 5.1), or it can be set with the two rotary switches as indicated on the connection diagram. The left switch selects the left decimal digit and the right switch the right decimal digit of the Station Address.
  • Page 12: Appendix B. Troubleshooting

    .The Profibus card may be faulty.  If this is the case, then there will be an error message in the FieldServer RUI error screen indicating that the card could not be reached. Check for this message. If it is there, try opening up the FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com...
  • Page 13 FS-8700-113 X30 Profibus DP Slave Driver Manual Page 13 of 14 FieldServer and re-seating the card. If this does not help, contact FieldServer Technical support for jumper settings on the card, and further possible troubleshooting or return authorization. FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com...
  • Page 14: Appendix C. Vendor Information

    The following HMS APP note provides useful information. http://www.anybus.com/support/support.asp?PID=70&ProductType=Anybus-S Please note that this link and document is provided for information only and is not maintained by FieldServer. FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com...