SIZING AND SELECTING UNITS
See chart below:
Square Footage
(For ducts at least 16" wide)
Up to 2000
4000
Notes:
For applications with multiple systems, we recommend one unit
per system.
For larger applications, multiple units are recommended.
Contact technical support at 1-252-522-3031 for sizing.
Each unit will require its own transformer.

INSTALLATION

1.
Locate a suitable location for the unit downstream from the 'A' coil in
the supply plenum or in the return plenum; preferably downstream from
the air filter. For optimum "cleaning" effect on the 'A' coil, mount the
unit in the supply plenum as close as possible to the 'A' coil.
(See Figure 1)
CAUTION: Investigate and determine the location of the A coil prior to
drilling holes in duct for mounting unit.
NOTE: For duct board installation, refer to enclosed bagged assembly
containing mounting plate and instructions.
2.
Apply supplied mounting template to air duct in either
a vertical or horizontal position. (See Figure 2) Leave
template mounted to duct for future reference.
" diameter mounting holes at positions indicated
3.
Drill
1
8
on template. (See Figure 3)
4.
Cut out the large opening (1-
(See Figure 3)
5.
Using a
" to
" drill bit, drill a viewport hole as
1
1
4
2
indicated on the template. (Figure 3)
6.
Optional Light Shield: The light shield may be mounted
at virtually any angle. However, when deciding on a
suitable location, the mounting screw head can not be in
the shaded area of template. (See Figure 4 to view areas
to avoid.)
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness.
Never operate the UV-Aire
UV-Aire
Volts Watts Amps Hz
1
24
2
24
" hole) on the template.
1
2
Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands.
23
1.3
60
46
2.6
60
page 3
Head of mounting screw CANNOT be
located in shaded area.
Figure 1
Figure 2
Figure 3
Figure 4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Uv-aire uv-16Uv-aire uv-24

Table of Contents