GENERAL INFORMATION

The UV-Aire unit uses technology that is recommended by doctors who state that "ultraviolet radiation,
properly integrated with heating, ventilating, and air conditioning systems, shows the most promise as a
widely applicable means of air disinfection".
Optional UVC-Light Shield:
Designed to mount at virtually any angle to guard or shield certain plastics,
wiring or air filters that may be affected by UVC light.
SIZING AND SELECTING UNITS
Square Footage
Up to 2000
4000
Notes:
For applications with multiple systems, we
recommend one unit per system.
For larger applications, multiple units are
recommended. Contact technical support at
1-252-522-3031 for sizing.

INSTALLATION

1.
Locate a suitable location for the unit
downstream from the 'A' coil in the supply
plenum or in the return plenum; preferably
downstream from the air filter. For optimum
"cleaning" effect on the 'A' coil, mount the
unit in the supply plenum as close as possible
to the 'A' coil. (See Figure 1)
CAUTION: Investigate and determine the
location of the A coil prior to drilling holes in duct for mounting
unit.
NOTE: For duct board installation, refer to enclosed bagged
assembly containing mounting plate and instructions.
2.
Apply supplied mounting template to air duct in either a vertical
or horizontal position as shown in Figure 2. (Leave template
mounted to duct for future reference.)
3.
Drill
" diameter mounting holes at positions indicated on
1
8
template. (See Figure 3)
Richard Riley, M.D. "Airborne Infection: The American Journal of Medicine,
1
Sept. 1974, Vol. 57 - 5/16/01
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness.
Never operate the UV-Aire Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands.
1
UV-Aire
(For ducts at least 16" wide)
1
2
Volts
Watts
Amps
120
30
.5
120
30
.5
page 3
Optional UVC-Light Shield
Hz
60
60
Figure 1