If You Have Duct Board - Field Controls UV-AIRE UV-12 Owner's Manual

Field controls air purifying system owner's manual
Hide thumbs Also See for UV-AIRE UV-12:
Table of Contents

Advertisement

IF YOU HAVE DUCT BOARD:

a.
Mount the supplied metal mounting plate onto the duct with duct tape in either a vertical or horizontal
position as shown in Figures 2B and 3.
b.
Bend tabs outward as shown in Figure 4.
c.
Using a knife or blade, cut out a rectangle opening in the duct using the mounting plate as a template.
(See Figure 5)
d.
Remove the cut piece of duct. (See Figure 6)
e.
Bend both tabs down and through duct at first bend point. (See Figures 7 and 8)
f.
Bend both tabs at the second bend point up or down to pinch the duct material and grip the duct
material. (See Figures 9 and 10)
g.
Using a screwdriver or pointed object, locate mounting holes by poking holes through the duct tape.
(See Figure 11)
Figure 3
Figure 7
3.
Remove base unit and cover from box.
4.
Apply supplied Duct Seal Kit according to instructions
included in kit. (See Figure 12)
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness.
Never operate the UV-Aire Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands.
Figure 4
Figure 9
Figure 8
page 4
Figure 5
Figure 10
Figure 6
Figure 11
Figure 12