Download Print this page

Limited Warranty - Pullman Holt 102ASB-12PD Operation & Care Instructions

Dry asbestos vacuum cleaner

Advertisement

Handle Assembly Guide:
1. Remove and carefully set aside motor head and HEPA fi lter.
2. Remove the .250-20x1.25 hex bolt and .250-20 hex nut from
the bottom handle support.
3. Loosen the hex nuts that secure the clamps on the tank. Slide
handle through the two clamps mounted on the tank and onto
the handle support.
4. Reinstall the bolt and nut through the handle and handle
support.
5. Tighten the handle clamps and bottom handle support.
Wheel & Caster Assembly Guide:
Washer
Hub Cap Cover
B980556
B703549
Hub Cap
B910073
1. Slide rear wheels onto axle of frame. Snap on hub cap
covers.
2. Insert and push casters into the holes located at the front of
the vacmobile metal frame.
3. Lock the casters in place with the hub nuts, using a rubber
hammer.
The vacuum cleaner is warranted for 1 year from the date of purchase as
shown on your distributor's invoice. Parts not covered under warranty are
power cords, fi lters, motor brushes and squeegee blades. The warranty
covers only failure due to defective parts or workmanship and will be
ABOUT THE VACUUM CLEANER
Axle
Hub Cap
B910073
Caster
B910518
Wheel
B703544
(1)

LIMITED WARRANTY

10702 N 46th Street • Tampa, FL 33617
(813)971-2223 • fax (813)971-6090
www.pullman-holt.com
With HEPA Filter Assembly in place, the motor head securely
clamped, and the metal hose adapter connected to the inlet, plug
the power cable into the proper outlet. Select the appropriate
hose, wand and/or tool and connect to the hose adapter. The
vacuum cleaner is ready for dry use.
Disposable Bag Changing:
Overfi lling the bag will result in loss of vacuum effi ciency. The
recommended bag replacement procedure is as follows:
1. Remove vacuum head and HEPA fi lter.
2. Tape a 6-mil poly bag over the canister so that the canister is
completely enclosed.
3. Using the poly bag as a glove, disengage the paper bag from
the vacuum inlet stem inside the canister.
4. Invert the canister so that the paper bag falls into the poly bag.
Seal the poly bag and dispose as prescribed by law.
5. Attach a new paper bag to the vacuum inlet securely and fold
(2 & 3)
the top of the bag down so it does not interfere with the HEPA
fi lter.
6. Replace the HEPA fi lter and motor head.
7. Thoroughly vacuum the work area to recover any asbestos
dust which may have been dropped.
invalidated by improper application and abuse.
In NO circumstance should you return a failed unit to the factory. If you
experience any problems with your vacuum during the warranty period,
contact the Customer Service.
B704009
04/12

Advertisement

loading