Reference
Designator
C1 – C8
Capacitor, AL, 50,000 F, +100-10 %, 15 V, Hi Term
CR1, CR3
Diode, SI, 50 PIV, 20.0 A
CR2, CR4
Diode, SI, 50 PIV, 20.0 A
F2, F3
Fuse, 0.25 x 1.25, 30 A, 32 V, Fast
H14
Nut, Machine, Hex, BR, ¼-28
H15
Washer, Shoulder, Fiber, 0.250 ID
H16
Screw, Machine, PH, P, Steel, 10-32 x 0.375
H17
Nut, Machine, Hex, Steel, 8-32
H18
Screw, Machine, PH, P, Steel, 10-32 x 0.375
H19
Washer, Flat, Steel, 0.265, 0.500, 0.031
H20
Washer, Flat, Teflon, 0.366 x 0.266 x 0.050
MP35
Heatsink, Diode
MP36
Insulation Part, Diode, Silicone, Washer
MP37
Bus, Capacitor
R2, R5
Resistor, CC, 100, 10 %, 2 W
XF2, XF5
Fuse, Clip, PCB, 1/4 x 1-1/4
Table 5-4. A3 Capacitor Bus PCB Assembly
Description
List of Replaceable Parts
Service Centers
Fluke
Total
Part No.
Quantity
432525
8
483206
2
483214
2
500793
2
110619
9
110833
4
159749
5
110544
10
114314
16
110718
4
543314
4
502179
1
500785
4
497982
1
109934
2
756460
4
5
5-19