Load-Sharing Examples; Verifying The Load-Sharing Configuration; Switch Port-Mirroring - Extreme Networks ExtremeWare XOS Guide Manual

Concepts guide
Hide thumbs Also See for ExtremeWare XOS Guide:
Table of Contents

Advertisement

Switch Port-Mirroring

configure sharing <master_port> delete ports <port_list>

Load-Sharing Examples

This section provides examples of how to define load-sharing on modular and stand-alone switches.
Cross-Module Load Sharing on a Modular Switch
The following example defines a load-sharing group that contains ports 9 through 12 on slot 3, ports 7
through 10 on slot 5, and uses the first port in the slot 3 group as the master logical port 9:
enable sharing 3:9 grouping 3:9-3:12, 5:7-5:10
In this example, logical port 3:9 represents physical ports 3:9 through 3:12 and 5:7 through 5:10.
When using load sharing, you should always reference the master logical port of the load-sharing group
(port 3:9 in the previous example) when configuring or viewing VLANs. VLANs configured to use
other ports in the load-sharing group will have those ports deleted from the VLAN when load sharing
becomes enabled.
Single-Module Load Sharing on a Modular Switch
Single-module load sharing is supported on all modular switches. The following example defines a
load-sharing group that contains ports 9 through 12 on slot 3 and uses the first port as the master
logical port 9:
enable sharing 3:9 grouping 3:9-3:12
In this example, logical port 3:9 represents physical ports 3:9 through 3:12.
When using load sharing, you should always reference the master logical port of the load-sharing group
(port 3:9 in the previous example) when configuring or viewing VLANs. VLANs configured to use
other ports in the load-sharing group will have those ports deleted from the VLAN when load sharing
becomes enabled.

Verifying the Load-Sharing Configuration

The screen output resulting from the
command lists the ports that are involved in
show ports sharing
load sharing and the master logical port identity.
Switch Port-Mirroring
Port-mirroring configures the switch to copy all traffic associated with one or more ports. The monitor
port can be connected to a network analyzer or RMON probe for packet analysis. The system uses a
traffic filter that copies a group of traffic to the monitor port.
The traffic filter can be defined based on one of the following criteria:
• Physical port—All data that traverses the port, regardless of VLAN configuration, is copied to the
monitor port.
ExtremeWare XOS 10.1 Concepts Guide
59

Advertisement

Table of Contents
loading

This manual is also suitable for:

Extremeware xos 10.1

Table of Contents