Interpreting POST results

Interpreting POST results
POST is a system check that is performed each time the switch is powered on, rebooted, or reset.
During POST, the LEDs flash either amber or green. Any errors that occur during POST are listed in
the error log.
Complete the following steps to determine whether POST completed successfully and whether any
errors were detected.
1. Verify that the switch LEDs indicate that all components are healthy.
2. Verify that the switch prompt displays on the terminal of a computer workstation connected to
3. Review the switch system log for errors. Any errors detected during POST are written to the
For information about all referenced commands, and on accessing the error log, refer to the Fabric
OS Administrator's Guide. For information about error messages, refer to the Fabric OS Message
Reference.

Brocade 6520 maintenance

The Brocade 6520 is designed for high availability and low failure; it does not require any regular
physical maintenance. It includes diagnostic tests and field-replaceable units, described in the
following sections.

Installing an SFP+ transceiver

The Brocade 6520 supports only Brocade-branded 8 Gbps and 16 Gbps SFP+ optical transceivers.
For the Fibre Channel connections, the Brocade 6520 uses SFP+ transceivers that support any
combination of Short Wavelength (SWL), Long Wavelength (LWL), and Extended Long Wavelength
(ELWL) optical media.
If you use an unqualified transceiver, the switchShow command output shows the port in a
Mod_Inv state. Fabric OS also logs the issue in the system error log.
For this task, refer to
Complete the following steps to install an SFP+ transceiver.
22
Refer to
Table 7
and
Table 8
more LEDs do not display a healthy state, verify that the LEDs on the switch are not set to
"beacon" by entering the switchShow command to detect if beaconing is active.
the switch.
If there is no switch prompt when POST completes, press Enter. If the switch prompt still does
not display, try opening a Telnet session or accessing the switch through another management
tool. If this is not successful, the switch did not successfully complete POST. Contact your
switch supplier for support.
system log, accessible through the errShow command.
Figure 5
for descriptions and interpretations of LED patterns. If one or
or
Figure
6.
Brocade 6520 Hardware Reference Manual
53-1002705-01