Electronic Control / "Power-Outage Memory; Water Flow Indicator; Salt Efficiency - Whirlpool WHES20 Installation And Operation Manual

Demand controlled water softener
Table of Contents

Advertisement

"Power-
Outage Memory"
If electrical power to the water softener is lost, "memory"
built into the timer circuitry will keep all
settings for up to eight hours. While the power is out, the display is blank and the water softener will
not regenerate.
When electrical power is restored, the following will occur.
1.
You have to reset the present
time only if the display
is flashing.
The HARDNESS
and
RECHARGE
TIME never require resetting
unless a change is desired.
Even if the clock is
incorrect after a long power outage, the softener works as it should to keep your water soft.
However, regenerations
may occur at the wrong time of day until you reset the clock to the correct
time of day.
If the water softener was regenerating
when power was lost, it will now finish the cycle.
NOTE:
Water Flow Indicator
Whenever
the softener has water flowing from the outlet port, the display will show water droplets
scrolling down the right hand side of the screen. The faster the water flow, the faster the droplets will
flash.
3:k'-I
..._
roplets indicate water
flow through softener
Salt Efficiency
When this feature is ON, the water softener will operate at salt efficiencies
of 4000 grains of hardness
per pound of salt or higher. (May recharge more often using smaller salt dosage and less water). The
softener is shipped in the OFF setting.
1.
Press and hold the O
PROGRAM
button until the following screen is displayed.
.
)
Once in this display, press the O
i ROGRAM
button and one of the following two displays is
shown.
n
0FF]
un
_"_
{1_
Eficiency
Icon
Press the Z_
Up or _
Down buttons to set On or Off. When set to On, the efficiency icon will
be displayed in the lower left hand corner of the normal run display.