LG LSC27990TT Service Manual page 47

Sxs refrigerator
Hide thumbs Also See for LSC27990TT:
Table of Contents

Advertisement

ICEMAKER ANDDISPENSER WORKING PRINCIPLES ANDREPAIR
2-5. Function
TEST
1. This is a forced operation for TEST, Service, cleaning, etc. It is operated by pressing and holding the Fill Key for 3 seconds.
2. The test works only in the Icemaking Mode. It cannot be entered from the Harvest or Fill mode. (If there is an ERROR, it
can only be checked in the TEST mode.)
3. Caution!
If the test is performed before water in the icemaker is frozen, the ejector will pass through the water. When the
Fill mode begins (Stage 4), unless the water supply has been shut off, added water will overflow into the ice bin. If the
control doesn't operate normally in the TEST mode, check and repair as needed.
4. After water is supplied, the normal CYCLE is followed: icemaking =-) Harvest =-) Fill --> Park Position.
5. Five seconds after Stage 5 is completed, the Ice Maker returns to MICOM control. The time needed to supply water
resets to the pre- test setting.
Diagnosis TABLE
STAGE
ITEMS
INDICATOR
REMARKS
Five seconds after heater starts, a
1
HEATER
heater will go off if the temperature by
sensor is higher than 20°C
Five seconds after heater starts, you
2
MOTOR
can confirm that a motor is moving.
HALL IC I
_
After the icemaker detects that ice has been
3
(detection of
_
made, the motor and heater are off but on
position)
standby until the cycle is cancelled.
HALL IC I1
You can confirm HALL IC detection of
4
(detection of
position.
position)
Two seconds after detection of initial
5
VALVE
position, you can confirm that valve is on.
6
Reset
Return to Status prior to
Five seconds after fifth stage is completed,
TEST MODE
The icemaker resets to initial status.
3. DEFECT
DIAGNOSIS
FUNCTION
3-1. ERROR
CODES
shown
on Icemaker
water
supply
control
panel
NO
DIVISION
INDICATOR
CONTENTS
REMARKS
Mark time to
Display switch
1
Normal
supply
None
operates properly
Icemaking
_
Make sure that the wire
2
Sensor
_
Open or short-circuited
wire
on each sensor is
malfunction
connected.
ERROR indicators in table can be checked only in TEST mode.
- 47 -