MICOM FUNCTION
ALL DISPLAYPARTSTURN OFF OTHERTHAN FREEZER ROOMNOTCH TEMPERATUREDISPLAYAND REFRIGERATORROOM NOTCH TEMPERATUREDISPLAY(FAILURECODE INDICATIONPART)
IN CASEOF INDICATINGFAILURE MODES(EXCEPT FORNOTE1, NOTE2)
NOTE1 ) FREEZER ROOM NOTCHTEMPERATUREDISPLAY AND REFRIGERATORROOMNOTCH TEMPERATUREDISPLAY(FAILURECODE INDICATIONPART)ARE NORMALLY INDICATED INABNORMAL
AMBIENT SENSOR, AND "Er" INDICATED ON THE AMBIENT TEMPERATUREDISPLAY(EXCEPTFORTHE AMBIENT TEMPERATUREDISPLAY,OTHER DISPLAY PARTSARE INDICATED NORMALLY)
NOTE 2) R2-SENSOR, WATER-TANK SENSOR AND OPTICHILL SENSOR IS NOT INDICATED ON THE FAILURE INDICATING PART BUT INDICATED IN CHECKING ALL DISPLAY PARTS
(WHEN PRESSING THE TEMPERATRUE
AND
4))
_
BUTTON IN THE LOCK STATUS FOR MORE THAN 1 SECOND).
R2-SENSOR(MIDDLE ROOM)
[-
N O R U A L : DISPLAY PART GRAPHIC ON THE ,_/C_ PARTTURNS ON
ABNORMAL
DISPLAY PART GRAPHIC ON THE _C)PART TURNS OFF
WATER-TANKSENSOR
[-
N O R M A L : DISPLAYPARTGRAPHICONTHE_.)_
PARTTURNSON
ABNORMAL
DISPLAY PART GRAPHIC ON THE @ PART TURNS OFF
THE OTHER DISPLAY GRAPHICS
TURN ON
OPTI-FRESH
SENSOR
[-
N O R M A L : DISPLAYPARTGRAPHICONTHE(E_PARTTURNSON
ABNORMAL
DISPLAY PART GRAPHIC ON THE ,_F_ PART TURNS OFF
(2)TEST FUNCTION
TESTKEYEXISTS ONPWBASSY, M AINBOARD.
MODE
OPERATION
CONTENTS
REMARKS
1. CONTINUOUS
OPERATION
OF COMPRESSOR
4. MAIN STEPPING
MOTOR DAMPER
IS COMPLETELY
PRESS
TEST BUTTON
ONCE
2. CONTINUOUS
OPERATION
OF FREEZING
BLDC MOTOR
OPENED
(OPEN
OF BAFFLE)
FREEZING
FAN TURNS
OFF
TEST1
<STRONG
COLD MOOE>
(HIGH-SPEED
RPM) AND COOLING
BLDC MOTOR
5. ALL DISPLAY GRAPHICS
TURNS
ON
IN DOOR OPENING
3. DEFROST
HEATER
TURNS
OFF
PRESS TEST BUTON ONCE AT THE TEST
1. COMPRESSOR
OFF
4. MAIN STEPPING
MOTOR DAMPER
IS COMPLETELY
RETURN
TO THE NORMAL
TEST2
MODE 1 S-ATUS
2. FREEZING
BLDC MOTOR AND COOLING
BLDC MOTOR
CLOSED
(CLOSING
OF BAFFLE)
MODE WHEN THE
<FORCED DEFROST MODE>
TURN OFF
5. ALL DISPLAY GRAPHICS TURNS OFF (ONLY "FAILURE CODE
DEFROST
SENSOR
IS
3. DEFROST
HEATER
TURNS
ON
INDICATION PART"TURNS
ON FOR '22"STATUS)
ABOVE
+S°C
NORMAL
PRESS TEST 8UTON ONCE AT THE TEST
COMPERSSOR WILL OPERATE
STATUS
MODE 2 STATUS
RETRUING
TO INITIAL
STATUS
AFTER DELAY FOR 7 MINUTES
;_-" L CD check function: If simultaneously
pressing TEMPERATURE
and 4 ))_' button for a second in the lock status, a
back light is turned on and all display LCD graphics on. If releasing the button, the LCD graphic
displays the previous status.