KitchenAid KBZU122VSS Installation Instructions And Use & Care Manual page 14

Outdoor built-in dual side burners installation instructions
Table of Contents

Advertisement

Available languages

Available languages

7=
The tank tray for the 20 Ib LP gas fuel tank must be adjusted
so that the bottom of the tank tray is %" (0.32 cm) above the
cabinet door opening and is level. The top nut on each of the
mounting brackets is to be loose. Turn the bottom nuts
counterclockwise
to raise the tank tray and turn the bottom
nuts clockwise to lower the tank tray. When the tank tray is
level and slides in and out without touching the cabinet door
opening at the bottom or top with the 20 Ib LP tank installed,
tighten the top nuts against the adjustment flange.
A
B
A. Top nut loosened
B. Top nut tightened
NOTE: A bracket or shelf (not supplied) that is large enough
to keep a second 20 Ib LP gas fuel tank from being stored in
the storage area under the side burner is required to be
mounted inside the island.
Make Gas Connection
Gas Connection to a 20 Ib LP Gas Fuel Tank
Explosion Hazard
Use a new CSA international
approved
"outdoor"
gas supply
line.
Securely tighten
all gas connections.
if connected to LP, have a qualified
person make sure
gas pressure does not exceed 11" (28 crn) water
column.
Examples of a qualified
person include:
licensed heating personnel,
authorized
gas company
personnel, and
authorized
service
personnel.
Failure to do so can result in death, explosion,
or fire.
If converting to local LP or Natural gas, follow the instructions
in
the "Gas Conversions"
section.
IMPORTANT: A 20 Ib LP gas fuel tank must be purchased
separately.
IMPORTANT: The gas pressure regulator/hose
assembly
supplied with the side burner must be used. Replacement gas
pressure regulator/hose
assembly specific to your model, is
available from your outdoor side burner dealer.
To Install the 20 Ib LP Gas Fuel Tank:
1. Open cabinet doors.
2. Pull out the tank tray.
Tank tray
3. Place the 20 Ib LP gas fuel tank bottom collar into the
mounting hole in the tank tray.
4. Tighten the locking screw against the bottom collar of the
20 Ib LP gas fuel tank to secure.
5=
B
C
A. Locking screw
B. Mounting hole
C. Bottom collar
Screw the gas pressure regulator/hose
assembly to the 20 Ib
LP gas fuel tank as shown. (To disconnect,
turn off the gas
supply to the 20 Ib LP gas fuel tank, then unscrew the gas
pressure regulator/hose
assembly from the 20 Ib LP gas fuel
tank as shown.)
B
A
A. 20 Ib LP gas fuel tank
B. Gas pressure
regulator/hose
assembly
6. Turn on the gas supply. Wait a few minutes for gas to move
through the gas line.
7. Test all connections
by brushing on an approved
noncorrosive
leak-detection
solution. Bubbles will show a
leak. Correct any leak found.
8. Slide tank tray back into the cabinet.
9. Go to "Plug in Side Burner" in this section.