KitchenAid KBZU122VSS Installation Instructions And Use & Care Manual page 11

Outdoor built-in dual side burners installation instructions
Table of Contents

Advertisement

Available languages

Available languages

The 20 Ib LP gas fuel tank must be mounted and secured.
Door Style Tank Tray
1. Open cabinet doors.
2. Pull out the tank tray.
Tank tray
3. Place the 20 Ib LP gas fuel tank bottom collar into the
mounting hole in the tank tray.
4. Tighten the locking screw against the bottom collar of the
20 Ib LP gas fuel tank to secure.
B
C
A. Locking screw
B. Mounting hole
C. Bottom collar
5. Slide tank tray back into the cabinet.
6. Close cabinet doors.
Local LP Gas Supply Conversion
Conversion must be made by a qualified gas technician. The
qualified gas technician shall provide the gas supply to the
selected side burner location in accordance
with the National
Fuel Gas Code ANSI Z223.1/NFPA 54 - latest edition, and local
codes. For conversion to local LP, the convertible regulator in the
conversion kit supplied with the side burner must be used.
IMPORTANT: The gas installation must conform with local
codes, or in the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1/NFPA 54 - latest edition. The qualified
LP gas technician shall provide the LP gas supply to the selected
side burner location in accordance with the National Fuel Gas
Code, ANSI Z223.1/NFPA
54 and local codes.
Follow instructions
for converting to local LP gas in the "Gas
Conversions"
section.
A. New CSA International
approved
"outdoor"
flexible gas supply line
B. Rear of side burner
C. To local LP gas supply
The gas supply line shall be equipped with an approved shutoff
valve. This valve should be located in the same area as the side
burner and should be in a location that allows ease of opening
and closing. Do not block access to the shutoff valve. The valve
is for turning on or shutting off gas to the side burner.
B
A. Gas supply line
B. Shutoff valve "open" position
C. To side burner
Natural Gas Conversion
Conversion must be made by a qualified gas technician. The
qualified Natural gas technician shall provide the Natural gas
supply to the selected side burner location in accordance with
the National Fuel Gas Code ANSI Z223.1/NFPA 54 - latest
edition, and local codes. For conversion to Natural gas, the
Natural gas conversion kit supplied with the side burner must be
used.
IMPORTANT: The gas installation must conform with local
codes, or in the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1/NFPA 54 - latest edition.
To convert to Natural gas, the Natural Gas Conversion Kit
supplied with the side burner must be used. Follow instructions
for converting to Natural gas in the "Gas Conversions"
section.
C
A. New CSA International
approved
"outdoor"
flexible gas supply line
B. Rear of side burner
C. To Natural gas supply
The gas supply line shall be equipped with an approved shutoff
valve. This valve should be located in the same area as the side
burner and should be in a location that allows ease of opening
and closing. Do not block access to the shutoff valve. The valve
is for turning on or shutting off gas to the side burner.
B
A. Gas supply line
B. Shutoff valve "open" position
C. To side burner
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kbzu242vssKbzu122tssKbzu242tss

Table of Contents