INSTALLATION
REQUIREMENTS
Gather the required tools and parts before starting installation.
Read and follow the instructions
provided with any tools listed
here.
Tools needed
•
Level
•
Drill
•
1W' (3 cm) drill bit
•
3/32"(2.4 mm) drill bit
•
1/8"(3 mm) drill bit
•
Pencil
•
Wire stripper or utility knife
•
Tape measure or ruler
•
Pliers
•
Caulking gun and weatherproof
caulking compound
•
Vent clamps
•
Jigsaw or keyhole saw
•
Flat-blade screwdriver
•
Metal snips
•
Phillips screwdriver
•
Scissors
Parts needed
•
Home power supply cable
•
1 - 1/2"(12.7 mm) UL listed or CSA approved strain relief
•
2 UL listed wire connectors
For vented installations,
you will also need:
•
1 wall or roof cap
•
Metal vent system
For non-vented
(recirculating)
installations,
you will also
need:
•
Recirculating
Kit Part Number W10272172 for non-vented
(recirculating)
installations only. See "Assistance
or Service"
section to order.
Parts supplied
Remove parts from packages. Check that all parts are included.
•
2 metal grease filters for 30" (76.2 cm) models
3 metal grease filters for 36" (91.4 cm) models
•
2 - chimney mounting brackets
•
6 - #10 Phillips head mounting screws
•
4 - Chimney cover mounting screws
•
Upper chimney cover
•
Lower chimney cover
•
Damper
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the
installer's responsibility
to comply with installation clearances
specified on the model/serial rating plate. The model/serial
rating
plate is located inside the range hood on the rear wall of the
range hood.
Canopy range hood location should be away from strong draft
areas, such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given
dimensions
provide minimum clearance.
Grounded electrical outlet is required. See "Electrical
Requirements"
section.
The canopy range hood is factory set for venting through the roof
or through the wall. For non-vented (recirculating) Installation see
"Non-vented
(recirculating) Installations"
in "Prepare Location"
section. Recirculating
Kit Part Number W10272172 is available
from your dealer or an authorized parts distributor.
All openings in ceiling and wall where canopy range hood will be
installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured
Home Construction
Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction
and Safety, Title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured
Home
Installation 1982 (Manufactured
Home Sites, Communities
and
Setups) ANSI A225.1/NFPA 501A*, or latest edition, or with local
codes.
Product Dimensions
A
18V4" (46.4 crn)
30" (76.2 crn)
j_
35_" (89.9 crn)
1_
(50.2crn)
A. Min. for vented installation - 29" (73.7 cm)
Min. for non-vented installation
- 327/2" (82.6 cm)
Max. 447/2'' (113.0 cm)
Non-vented (recirculating)
Installations
For non-vented (recirculating)
installations, a Recirculating
Kit
Part Number W10272172 is required. See "Assistance or
Service" section to order.