KitchenAid KEHS02RWH0 Use & Care Manual page 9

Front-loading electric dryer
Table of Contents

Advertisement

Available languages

Available languages

Power Supply Cord
Direct Wire
Fire Hazard
Use a new UL listed 30 amp power supply cord.
Use a UL _isted strain retief,
Disconnect
power before making e_ectrical connections.
Connect neutra_ wire (white or center wire) to center
terminal
(silver),
Ground wire (green or bare wire) must be connected
to
green ground connector.
Connect remaining
2 supply wires to remaining
2 terminals
(go_d).
Securely tighten
aimelectrica_ connections,
Failure to do so can result in death, fire, or
e_ectrical shock,
Fire Hazard
Use 10 gauge solid copper
wire,
Use a UL listed strain
relief,
Disconnect
power before making electrical
connections.
Connect neutral wire (white or center wire) to center
terminal
(silver).
Ground wire (green or bare wire) must be connected
to
green ground connector,
Connect remaining
2 supply wires to remaining
2 terminals
(gold).
Securety tighten
a_l electrica{ connections.
Failure to do so can result in death, fire, or
electrical
shock.
1. Disconnect
power.
2. Remove the hold-down
screw and terminal block cover.
D
Install strain relief.
Style 1: Power supply cord strain relief
Remove the screws from a %" (1.9 cm) UL listed strain
relief (UL marking on strain relief). Put the tabs of the two
clamp sections into the hole below the terminal block
opening so that one tab is pointing up and the other is
pointing down, and hold in place. Tighten strain relief
screws just enough to hold the two clamp sections
together.
A. Neutral ground wire
B. External ground conductor screw
C. Center, silver-colored
terminal block screw
D. Terminal block cover and hold-down
screw
A. Strain relief tab pointing
up
B. Hole below terminal block opening
C. Clamp section
D. Strain relief tab pointing
down