Explosion H azard
Keep flammable materials a ndvapors, s uchas
gasoline,
away from dryer.
Place dryer at least 18 inches (48 cm) above the floor
for a garage installation.
Failure to do so can result in death, e×plosion,
or fire.
You will need
A location that allows for proper exhaust installation. See
"Venting Requirements."
A separate 30-amp circuit.
If you are using a power supply cord, a grounded electrical
outlet located within 2 ft (61 cm) of either side of the dryer.
See "Electrical Requirements."
A sturdy floor to support the total dryer weight of 200 Ibs
(90.7 kg). The combined weight of a companion
appliance
should also be considered.
A level floor with a maximum slope of 1" (2.5 cm) under entire
dryer. If slope is greater than 1" (2.5 cm), install Extended
Dryer Feet Kit, Part Number 279810. Clothes may not tumble
properly and automatic sensor cycles may not operate
correctly if dryer is not level.
For a garage installation, you will need to place the dryer at
least 18" (46 cm) above the floor. If using a pedestal, you will
need to place the pedestal at least 6" (15.2 cm) above the
floor.
Do not operate your dryer at temperatures
below 45°F (7°C). At
lower temperatures,
the dryer might not shut off at the end of an
automatic cycle. This can result in longer drying times.
The dryer must not be installed or stored in an area where it will
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes or
sleeping quarters. Contact your local building inspector.
Installation
clearances
The location must be large enough to allow the dryer door to
open fully.
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door and
floor moldings.
Additional spacing of 1" (2.5 cm) on all sides of the dryer is
recommended
to reduce noise transfer.
Companion appliance spacing should also be considered.
Dryer Dimensions
(96.52
cm 1
i
(80cm)
_"
27"
%_
@(6&6
cm)
*Most installations require a minimum 51/2 '' (14 cm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."
Minimum
installation spacing for custom
undercounter
installation
The dimensions
shown are for the minimum spacing allowed.
Custom
undercounter
installation
- Dryer only
0" _
27" _}._-
0"
(Ocm)
_
(¢8.€cm)
_
(Ocm)
Minimum
installation spacing for recessed
or closet
installation,
with or without a pedestal
The dimensions shown are for the minimum spacing allowed.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.