Exmark Lawn Tractor Operator's Manual page 29

Exmark mfg. co. inc. lawn tractor operator's manual
Table of Contents

Advertisement

d)
If the oil level is low, wipe off the area around the oil fill cap, remove cap
and fill to the "FULL" mark on the dipstick. Use oil as specified in Engine
Owner's Manual. DO NOT overfill.
IMPORTANT: DO NOT operate the engine with the oil level below the
"LOW" (or "ADD") mark on the dipstick, or over the "FULL" mark.
5.1.2
Check battery charge:
Allowing batteries to stand for an extended period of time without recharging
them will result in reduced performance and service life. To preserve optimum
battery performance and life, recharge batteries in storage when the open
circuit voltage drops to 12.4 volts.
Note: To prevent damage due to freezing, battery should be fully charged
before putting away for winter storage.
a)
Check the voltage of the battery with a digital voltmeter. Locate the voltage
reading of the battery in the table below and charge the battery for the
recommended time interval to bring the charge up to a full charge of 12.6
volts or greater.
IMPORTANT: Make sure the negative battery cables are disconnected
and the battery charger used for charging the battery has an output of 16
volts and 7 amps or less to avoid damaging the battery (see chart below for
recommended charger settings).
Voltage
Reading
12.6 or greater
12.4 – 12.6
12.2 – 12.4
12.0 – 12.2
11.7 – 12.0
11.7 or less
IMPORTANT: For Kohler EFI units: Unplug the harness from the ECU
before performing any welding on the equipment.
5.1.3
Clean engine cooling system:
POTENTIAL HAZARD
♦ Excessive debris and damaged or missing rubber
baffles can cause the engine and hydraulic system to
overheat.
WHAT CAN HAPPEN
♦ Excessive debris around the engine cooling air intake
and inside of the pump drive belt compartment can
create a fire hazard.
HOW TO AVOID THE HAZARD
♦ Clean all debris from inside of pump drive belt
compartment daily.
Service Interval: Monthly
Percent
Charge
Charger Settings
100%
16 volts/7 amps
75 – 100%
16 volts/7 amps
50 – 75%
16 volts/7 amps
25 – 50%
14.4 volts/4 amps
0 – 25%
14.4 volts/4 amps
0%
14.4 volts/2 amps
Service Interval: Daily or more often in dry conditions
CAUTION
Information located:
On console decal 103-3996 below ignition switch
On decal 1-633462 behind seat on rubber heat
shield flap
- 24 -
Maximum
Charging Interval
No Charging Required
30 Minutes
1 Hour
2 Hours
3 Hours
6 Hours or More

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lazer z advantage series

Table of Contents