INSTALLATION INSTRUCTIONS
INTERIOR-MOUNTED VENTMOTOR
Determine which venting method is best for your application.
Vent system can terminate through either the wall or floor.
Island location
Front (standard) mounted
blower motor
Rear mounted blower
motor
q
. ............................................................
A
J
A. Down vent
NOTE: For island locations, the blower motor can be mounted for
right, left, or rear venting if needed for your application.
Most
island applications
would still require the venting to be directed
down through the floor.
Built-in cabinet locations
Island Location
Vent system installed under a concrete slab using PVC
sewer pipe.
Front (Standard) Mounted Blower Motor
i! i!
K
B
J
:___oo_,_ . ...........
_o :,_
.........
H
J
Rear Mounted Blower Motor
B
S
C
A
!
I
A. Down vent
B. Rear vent
C. Left vent
D. Right vent
I
II ..........
D
A. Wall cap
B. 6" (15.2 cm) round metal vent
C. 16" (40.6 cm) maximum
D. 6" (15.2 cm) round PVC sewer pipe
E. 6" (15.2 cm) round metal vent
F. 6" (15.2 cm) round PVC coupling
G. Concrete slab
H. 6" (15.2 cm) round PVC sewer pipe
I. 6" (15.2 cm) round 90 ° PVC sewer pipe elbow
J. Tightly pack gravel or sand completely
around pipe.
K. 6" (15.2 cm) round 90 ° PVC sewer pipe elbow
L. 6" (15.2 cm) round PVC coupling
M. 12" (30.5 cm) minimum
Calculating
Vent System
Length
It is recommended
that you use round vent instead of rectangular
vent, especially if elbows are required. If rectangular vent is
required, it should be transitioned
to 6" (15.2 cm) round vent as
soon as possible.
Maximum Length of Vent System
Vent
Length
6" (15.2 cm) round
35 ft (8.9 m)
3V4" x 10" (8.3 cm x 25.4 cm)
35 ft (8.9 m)
8