Jenn-Air JXDR7301VS0 Installation Instructions And Use & Care Manual page 10

30" and 36" (76.2cm and 91.4 cm) retractable(pop-up)downdraft vent sysiem
Table of Contents

Advertisement

Available languages

Available languages

5=
6=
Attach the left and right side end caps to the downdraft vent.
Place the end cap upon the overcounter support, slide the
tab into the slot and snap into place over the the plastic tabs.
A
A. Blower motor box
B. Support leg
7. Using 2 or more people, insert the downdraft vent into the
countertop cutout. Check that downdraft vent is parallel to
side of cutout and that mounting brackets overlap
countertop.
8. Move support legs down against cabinet floor. Place a level
against the front of the downdraft vent base and adjust until
downdraft vent is level vertically. Use a pencil to mark the top
of each leg on the downdraft vent and the location of the
support leg mounting holes on the cabinet floor.
9=
A
A. Level
B. Mark locations.
Remove downdraft vent from cutout. Drill starter holes at
each mounting screw location on the cabinet floor. Align top
of legs with pencil marks on the face of the downdraft vent.
Tighten screws in legs.
Determine
which direction is best for your installation.
When installed in a cabinet, vent system can exhaust through the
bottom, right, left or rear of the cabinet.
Bottom venting:
Downdraft vent is shipped with blower in down venting
position so no modification
is required. See "Complete
Installation" section.
Left or right venting:
1. Loosen the 2 hex/slotted head screws that attach the top
bracket that secures the motor to the vent box enough to
slide the bracket into the "Z" slots. This will move the bracket
away from the top mounting lip of the blower box and allow it
to tilt away from the vent box panel.
A
.... g
2=
@
A. Bracket with "Z" slots
B. Hex/slotted head screws (2)
Lift up the blower box from the bottom mounting channel.
3=
A. Blower box
A
B. Bottom mounting channel
Rotate it 90 degrees to the left or right so that the vent blower
damper is repositioned
in the direction needed. Do not twist
or bind the wires or disconnect
the wiring from the blower.
10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jxdr7361vs0Jxdr7301vs1Jxdr7361vs1W10201609c

Table of Contents