Performance
Data Sheet
SmartWater Filtration System
GSWF Cartridge
This system
has been tested according
to NSF/ANSI 42/53 for reduction
of the substances
listed below.
The concentration
of the indicated
substances
in water entering the system was reduced to a concentration
less than or equal to the permissible
limit for water leaving the system, as specified
in NSF/ANSI 42/53.*
(100% safety factors built in for unmetered
usage)
Standard
No. 42: Aesthetic
Effects
Parameter
Influent Challenge
Effluent
Chlorine
T&O
Particulate**
99.91%
Parameter
Turbiditg
Cgsts
Lead at pH 6.5
Lead at pH 8.5
Lindane
Atrazine
USEPA
MCL
USEPA
Influent
Average
1.845 mg/L
143,333#/mL
Concentration
Average
2.0 my/L+10%
< 0.05 mg/L
at least 10,000 particles/mL
29.83 #/mL
Standard
No, 53: Health
Effects
Maximum
0.05 mg/L
140 #/m L
Influent
Average
> 97.29%
99.98%
%Reduction
Minimum
96.43%
Influent Challenge
Effluent
% Reduction
MCL
1 NTU***
99.95% Reduction
0.015 mg/L
0.015 mg/L
0.0002 mg/L
0.003 mg/L
Average
10.3 NTU***
200,000 #/L
0.15 mg/L
0.14 mg/L
0.0216 mg/L
0.008 mg/L
Concentration
1+1 NTU***
Minimum 50,000 L
0.15 rag/L+10%
0.15 mg/L÷lO%
0.002 rag/L+10%
0.009 mg/L÷lO%
Average
0.106 NTU
0
< 0.001 mg/L
0.001 mg/L
< 0.00002 mg/L
< 0.002 mg/L
Maximum
0.14 NTU
0
< 0.001 mg/L
0.003 mg/L
< 0.00002 mg/L
< 0.002 mg/L
Average
98.97%
> 99.99%
> 99.33%
> 99.29%
99.07%
> 76.12%
Minimum
98.61%
> 99.99%
> 99.33%
97.86%
98.75%
> 66.67%
Min. Required
Reduction
> 50%
>85%
Min. Required
Reduction
0.5 NTU
> 99.95%
0.010 mg/L
0.010 mg/L
0.0002 mg/L
0.003 mg/L
* Tested using a flow rate of 0.5 gpm; pressure of 60 psig; pH of 7.5 ± 0.5; temp. of 68 ° ± 5°F (20° ± 3°C)
** Measurement in Particles/ml. Particles used were 0.5-1 microns
*** NTU=Nephelometric Turbiditg units
Operating
Specifications
[] Capacity: certified for up to 750 gallons (2,838 I);up to six months
[] Pressure requirement:
40-!20
psi (2.8-8.2 bar)
[] Temperature: 33-100% (0.6-38°C)
[] Flow rate: 0.5 gpm (1.9 Ipm)
General
Installation/Operation/Maintenance
Requirements
[] Flush new cartridge
at full flow for 3 minutes to purge out trapped
air.
[] Replace cartridge when flow becomes too slow.
Special
Notices
[] Installation instructions, parts and service availabilitg, and standard warrantg are included with the product when shipped.
[] This drinking water sgstem must be maintained according to manufacturer's instructions, including replacement of filter
cartridges.
[] Do not use with water that is microbiologicallg unsafe or of unknown qualitg without adequate disinfection before or after the
sgstem. Sgstems certified for cgst reduction
mag be used on disinfected
water that mag contain filterable
cgsts.
[] The contaminants
or other substances
removed or reduced bg this water treatment
sgstem are not necessarilg
in gour water.
[] Check for compliance with the state and local laws and regulations.
[] Note that while the testing was performed under standard laboratorg conditions, actual performance mag varg. Sgstems
must be installed and operated in accordance with manufacturer's recommended procedures and guidelines.
Sgstem tested and certified bg NSF International against Standard 42 for the reduction of
chlorine, taste and odor, particulate Class I and Standard 55 for the reduction of cgst, lead,
Lindane, Atrazine and turbiditg.
Manufactured for: General Electric Compang, Louisville, KY40225
45

Advertisement

loading