Patton electronics ipRocketLink 3086 User Manual page 99

G.shdsl integrated access device
Hide thumbs Also See for ipRocketLink 3086:
Table of Contents

Advertisement

Model 3086 G.SHDSL Integrated Access Device User Guide
– Class:UBR
– Port:atm
Click on the
Change
5. Click on Edit 'IP Interface.'
Verify or change if necessary the following Options parameters.
– Ipaddr:0.0.0.0
– Mask:0.0.0.0
– Dhcp:false
– MTU:1500
– Enabled:true
Click on the
Change
6. There is no gateway created in the IP routes submenu. Upon connecting, the server will provide this infor-
mation while setting up the PPP connection.
7. Go to G.SHDSL in the Configuration Menu, then the submenu Status. The Modem State should be
"deactivated." (If not, go to the Action and change it to deactivate.)
Then in the Action submenu under G.SHDSL, change Action to Start, then click on
Model 3086 (Central—Server) Configuration Steps (PPPoA Routed)
1. From the command line interface (CLI) via the RS-232 control port,
ip list interfaces
One IP interface was called ip1 with an IP address of 192.168.1.1 Change it to an IP address which is in
the same subnet as the Desktop PC. For example, to 192.168.172.3. The default IP mask is
255.255.255.0.
ip set interface ip1 ipaddress 192.168.172.3 255.255.255.0
DSLAM Connections with remote CPE units
button if changes were made.
button if changes were made.
4 • Basic Application Configurations
Action
.
99