6.
Touch inside the Compare Values field and select All or Any from the pop-up menu
All, the test will be true only if every waveform falls within the limit that you will set. By selecting Any, the
test will be true if just one waveform falls within the limit.
7.
Touch inside the Condition field in the ParamCompare mini-dialog and select a math operator from the
pop-up menu
8.
Touch inside the Limit field and enter a value, using the pop-up numeric keypad. This value takes the
dimension of the parameter that you are testing. For example, if you are testing a time parameter, the unit
is seconds.
9.
If you chose either WithinDeltaPct
inside the Delta field and enter a value.
Mask Testing
1.
Touch Analysis
2.
Touch one of the Qx tabs and a setup dialog for the position is shown.
3.
Touch inside the Source1 field and select a source from the pop-up menu.
4.
Touch inside the Condition field in the main dialog and select Mask Test
5.
From the Test portion of the dialog, make a selection in the Test is True when group of buttons
single waveform falls outside the mask.
6.
From the Show Markers section of the dialog, choose whether or not to have mask violations displayed.
7.
If you are loading a pre-existing mask, touch the Load Mask tab, and then the File button. You can then
enter the file name or browse to its location.
8.
If you want to make a mask from your waveform, touch the Make Mask tab.
9.
Touch inside the Ver Delta and Hor Delta fields and enter boundary values, using the pop-up numeric
keypad.
10. Touch the Browse button to create a file name and location for the mask if you want to save it.
11. Touch the Gate tab, then enter values in the Start and Stop fields to constrain the mask to a portion of the
waveform. Or, you can simply touch and drag the Gate posts, which initially are placed at the extreme left
and right ends of the grid.
WP700Zi-OM-E-RevA
or WithinDeltaAbs
Pass/Fail Setup... from the menu bar.