To Set The Alarm; Temperature; Specifications - Oregon Scientific RMR382A User Manual

Wireless indoor / outdoor thermometer with self-setting atomic clock

Advertisement

NOTE Press ZONE to set the US time zone options: (P)
Pacific, (M) Mountain, (C) Central and (E) Eastern.
NOTE The language options are (E) English, (F) French,
(D) German, (I) Italian, and (S) Spanish.
To switch the clock display:
Press MODE to toggle between:
Clock with seconds
Clock with day
Calendar
ALARM

To set the alarm:

1. Press ALARM to view the alarm.
display.
2. Press and hold ALARM for 2 seconds.
3. Press
or
to change the hour / minute settings.
4. Press ALARM to confirm.
To activate or deactivate the alarm:
Press ALARM when in the alarm display.
when the alarm is set.
To silence the alarm and reset it for the next day:
Press ALARM.

TEMPERATURE

To toggle the temperature unit:
Press °C / °F.
To view outdoor sensor temperature readings:
Press CHANNEL.
shows which remote sensor's data you are
viewing.
is permanently displayed in the indoor temperature
area.
To auto-scan between sensors:
Press and hold CHANNEL for 2 seconds. Each sensor's
data is displayed for 3 seconds.
To end auto-scan:
Press CHANNEL or MEM.
To toggle between current, minimum and maximum
records for the selected sensor:
Press MEM repeatedly.
To clear the records:
Press and hold MEM for 2 seconds.
TEMPERATURE TREND
Recent indoor / outdoor temperature trends are shown
by the trend icon.
RISING
STEADY
ICE WARNING
If the channel 1 sensor falls between 3°C to -2°C (37°F
to 28°F),
flashes to warn you that the temperature is
approaching freezing.
NOTE
The warning will automatically stop if the
temperature goes outside the ice-warning range.
HI / LO TEMPERATURE ALARM
An alarm can be set to sound if the sensor set to channel
1 records above or below a temperature of your choice.
To set alarm ON / OFF :
1. Press and hold TEMP HI / LO
.
2. Use
and
to select high / low temperature alarm.
Press TEMP HI / LO
to confirm.
3. Press
or
to set alarm ON / OFF and press
TEMP HI / LO
to confirm.
4. If alarm has been activated, use
the temperature.
5. Press TEMP HI / LO
to confirm.
To silence the hi / lo temperature alarm:
Press any key. The alarm resets automatically and will
resound if the hi / lo temperature selected is exceeded
again.
RESET
Press RESET to return the unit to the default settings.
RMR382A 086L004376-010_R1.indd 2
PRECAUTIONS
This product is engineered to give you years of
satisfactory service if you handle it carefully. Here are a
few precautions:
Do not immerse the unit in water. If you spill liquid over
it, dry it immediately with a soft, lint-free cloth.
Do not clean the unit with abrasive or corrosive
materials.
Do not subject the unit to excessive force, shock,
dust, temperature or humidity, which may result in
malfunction, shorter electronic life span, damaged
battery and distorted parts.
Do not tamper with the unit's internal components.
Doing so will invalidate the warranty on the unit and
will show on the
may cause unnecessary damage. The unit contains
no user-serviceable parts.
Only use fresh batteries as specified in the user's
instructions. Do not mix new and old batteries.
Do not use rechargeable batteries.
Remove batteries when storing the product for a long
time.
appears
Due to printing limitations, the displays shown in this
manual may differ from the actual display.
The contents of this manual may not be reproduced
without the permission of the manufacturer.
Do not dispose this product as unsorted municipal
waste. Collection of such waste separately for
special treatment is necessary.
NOTE The technical specifications for this product and
the contents of the user manual are subject to change
without notice.

SPECIFICATIONS

TYPE
Main unit
Dimensions
(L x W x D)
Weight
Remote unit
Dimensions
(L x W x D)
Weight
Temperature unit – °C / °F
Indoor range
Outdoor range
Resolution
Remote unit
RF frequency
Range
Transmission
FALLING
Channel no.
Clock
Synchronization
Clock display
Hour format
Calendar
Weekday in 5
languages
Alarm
Power
Main unit
Remote unit
NOTE We recommend that you use alkaline batteries
with this product for longer usage and lithium batteries in
temperatures below freezing.
ABOUT OREGON SCIENTIFIC
Visit our website (www.oregonscientific.com) to learn more
about Oregon Scientific products such as digital cameras;
or
to select
MP3 players; children's electronic learning products and
games; projection clocks; health and fitness gear; weather
stations; and digital and conference phones. The website
also includes contact information for our Customer Care
department in case you need to reach us, as well as
frequently asked questions and customer downloads.
We hope you will find all the information you need on our
website, however if you're in the US and would like to
contact the Oregon Scientific Customer Care department
directly, please visit:
www2.oregonscientific.com/service/default.asp
OR
Call 1-800-853-8883.
For international inquiries, please visit:
www2.oregonscientific.com/about/international.asp
FCC STATEMENT
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) This
device must accept any interference received, including
interference that may cause undesired operation.
WARNING
approved by the party responsible for compliance could
void the user's authority to operate the equipment.
NOTE
to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful
interference in a residential installation.
This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that
interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio
or television reception, which can be determined by
turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the
following measures:
DESCRIPTION
93 x 52 x 118 mm
(3.7 x 2.0 x 4.6 inches)
133 g (4.7 ounces) without
battery
DECLARATION OF CONFORMITY
96 x 50 x 22 mm
The following information is not to be used as contact
(3.8 x 2.0 x 0.9 in)
for support or sales. Please call our customer service
62 g (2.22 ounces) without
number (listed on our website at www.oregonscientific.
battery
com), or on the warranty card for this product) for all
inquiries instead.
-5°C to 50°C (23°F to 122°F)
We
-30°C to 60°C
(-22°F to 140°F)
Name:
Address:
0.1°C (0.2°F)
Telephone No.:
433MHz
Up to 30 meters (100 feet)
declare that the product
with no obstructions
Product No.:
Approx. every 40 seconds
Product Name:
1, 2 or 3
Manufacturer:
Auto or disabled
Address:
HH:MM
12hr AM/PM or 24hr
DD/MM or MM/DD
(E, G, F, I, S)
is in conformity with Part 15 of the FCC Rules. Operation
is subject to the following two conditions: 1) This device
may not cause harmful interference. 2) This device must
2-minute alarm
accept any interference received, including interference
that may cause undesired operation.
2 x UM-4 (AAA) 1.5V
batteries
1 x UM-3 (AA) 1.5V
battery
Changes or modifications not expressly
This equipment has been tested and found
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and
receiver.
Connect the equipment into an outlet on a
circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio / TV
technician for help.
Oregon Scientific, Inc.
19861 SW 95th Ave., Tualatin,
Oregon 97062 USA
1-800-853-8883
RMR382A
Wireless Indoor / Outdoor Thermometer
with Self-Setting Atomic Clock
IDT Technology Limited
Block C, 9/F, Kaiser Estate,
Phase 1,41 Man Yue St., Hung Hom,
Kowloon, Hong Kong
© 2006 Oregon Scientific. All rights reserved.
086L004376-010
4/3/06 10:32:10 AM

Hide quick links:

Advertisement

loading