INTRODUCTION
Congratulations on your purchase of the RMR182 Multi-
Channel In-Out Thermometer with 433MHz cable free sensor and
radio-controlled calendar clock.
The basic package comes with a main unit, which is the tempera-
ture and calendar clock station, and a remote unit, the thermo
sensor.
The main unit has a large display for indoor temperature,
calendar clock and temperatures collected and transmitted by the
remote unit. The main unit can support up to three remote units.
The main unit is capable of keeping track of the maximum and
minimum temperature of different sites. No wire installation is
required as the RMR182 operates at 433MHz.
As for the calendar clock, it is radio-controlled. It automatically
synchronizes its current time and date when it is brought within
an approximate 1500km radius of the radio signal generated from
Frankfurt, Germany (DCF77).
You can also set the calendar clock manually when it is off range.
Other features include four-language display, four-step crescendo
dual alarms and interchangeable display modes.
MAIN FEATURES: MAIN UNIT
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RMR182 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Oregon Scientific RMR182

  • Page 1 Cable Free Sensor and RF Clock MODEL: RMR182 USER'S MANUAL INTRODUCTION Congratulations on your purchase of the RMR182 Multi- Channel In-Out Thermometer with 433MHz cable free sensor and radio-controlled calendar clock. The basic package comes with a main unit, which is the tempera- ture and calendar clock station, and a remote unit, the thermo sensor.
  • Page 2 A FOUR-LINE LCD DISPLAY L [ ] BUTTON Facilitates easy reading of remote and indoor temperatures Advances the value of a setting and calendar clock M [ ] BUTTON ] RADIO-RECEPTION SIGNAL Decreases the value of a setting Indicates the condition of radio reception N [AL ON/OFF] BUTTON C TEMPERATURE TREND INDICATOR Enables or disables the alarms...
  • Page 3: Before You Begin

    A LCD DISPLAY MAIN FEATURES: REMOTE UNIT Displays the current temperature monitored by the remote unit B LED INDICATOR Flashes when the remote unit transmits a reading C °C/°F SLIDE SWITCH Selects between Centigrade (°C) and Fahrenheit (°F) D CHANNEL SLIDE SWITCH Designates the remote unit Channel 1, Channel 2 or Channel 3 E RESET BUTTON...
  • Page 4 3. Place the main unit as close as possible next to the remote unit 4. Install 2 alkaline batteries (UM-4 or “AAA” size 1.5V) strictly and reset the main unit after installing batteries. This will according to the polarities shown. ensure easier synchronization between the transmission and 5.
  • Page 5: Low Battery Warning

    Remote unit LOW BATTERY WARNING Wall-mount Table Stand When it is time to replace batteries, the low-battery indicator will show up when the corresponding channel is selected. The battery level of the main unit will be shown on the indoor temperature when it is running low.
  • Page 6: Temperature Trend

    If no signals are received, blanks "----" will be displayed and the TEMPERATURE TREND kinetic wave icon will show " ". Press [CHANNEL] and [MEMORY] simultaneously to enforce another search for about The temperature trend indicator on the screen shows the trend of 30 seconds.
  • Page 7: Disconnected Signals

    NOTE ON °C AND °F DISCONNECTED SIGNALS The unit of temperature display is selected with the °C/°F slide If without obvious reasons the display for a particular channel switch. Select °C for Centigrade or °F for Fahrenheit. goes blank, press [CHANNEL] and [MEMORY] to enforce an immediate search.
  • Page 8: About Radio Reception

    CALENDAR CLOCK DISPLAY MODES ABOUT RADIO RECEPTION The RMR182 supports four display modes in the sequence of: The RMR182 is designed to automatically synchronize its calen- dar clock once it is brought within range of the Frankfurt DCF77 radio signal.
  • Page 9: How To Stop An Alarm

    The radio reception signal will disap- pear. The unit will not respond to radio signals. The RMR182 has two alarms, ALARM 1 and ALARM 2. They can To enable the feature again, press the button for three seconds.
  • Page 10 When the alarm goes off the sound which will gradually increase TIME ZONE AND OFFSET TABLE in volume and repeating speed will be turned on for about 2 minutes unless the [( )] or [AL ON/OFF] button is pressed to ( •...
  • Page 11: Specifications

    RF Transmission Range : Maximum 30 meters SPECIFICATIONS Temperature sensing cycle : around 30 seconds Temperature Measurement Radio Controlled Clock Main unit Indoor Temperature measurement Maintime set and synchronized by Radio Signal DCF77 for Continental Central Europe Displayed IN temperature range : -9.9°C to +70.0°C 24 h display with hh : mm ss 14.2°F to 158.0°F Date Format : Day.
  • Page 12: Note On Compliance

    NOTE ON COMPLIANCE CAUTION This product complies to standards and specifications of BZT, - The content of this manual is subject to change without FCC and article number 334 of PTT. further notice. - Due to printing limitation, the displays shown in this Warning: Changes or modifications to this unit not expressly manual may differ from the actual display.