Oregon Scientific RMR182 User Manual

Oregon Scientific RMR182 User Manual

Multi-channel in-out thermometer with cable free sensor and rf clock
Hide thumbs Also See for RMR182:

Advertisement

MAIN FEATURES: MAIN UNIT
Multi-Channel In-Out Thermometer
with Cable Free Sensor and RF Clock
MODEL: RMR182
USER'S MANUAL
INTRODUCTION
Congratulations on your purchase of the RMR182 Multi-
Channel In-Out Thermometer with 433MHz cable free sensor and
radio-controlled calendar clock.
The basic package comes with a main unit, which is the tempera-
ture and calendar clock station, and a remote unit, the thermo
sensor.
The main unit has a large display for indoor temperature,
calendar clock and temperatures collected and transmitted by the
remote unit. The main unit can support up to three remote units.
The main unit is capable of keeping track of the maximum and
minimum temperature of different sites. No wire installation is
required as the RMR182 operates at 433MHz.
As for the calendar clock, it is radio-controlled. It automatically
synchronizes its current time and date when it is brought within
an approximate 1500km radius of the radio signal generated from
Frankfurt, Germany (DCF77).
You can also set the calendar clock manually when it is off range.
Other features include four-language display, four-step crescendo
dual alarms and interchangeable display modes.
1
RMR182_EN
1
8/16/04, 2:58 PM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RMR182 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Oregon Scientific RMR182

  • Page 1: Main Unit View

    Cable Free Sensor and RF Clock MODEL: RMR182 USER'S MANUAL INTRODUCTION Congratulations on your purchase of the RMR182 Multi- Channel In-Out Thermometer with 433MHz cable free sensor and radio-controlled calendar clock. The basic package comes with a main unit, which is the tempera- ture and calendar clock station, and a remote unit, the thermo sensor.
  • Page 2 A FOUR-LINE LCD DISPLAY Facilitates easy reading of remote and indoor temperatures and calendar clock ] RADIO-RECEPTION SIGNAL Indicates the condition of radio reception C TEMPERATURE TREND INDICATOR Indicates the trend of temperature changes ] BATTERY-LOW INDICATOR (REMOTE SENSOR) Activates when the remote-sensor battery is low ] BATTERY-LOW INDICATOR Activates when the battery is low ] / [...
  • Page 3: Remote Unit View

    MAIN FEATURES: REMOTE UNIT RMR182_EN A LCD DISPLAY Displays the current temperature monitored by the remote unit B LED INDICATOR Flashes when the remote unit transmits a reading C/ F SLIDE SWITCH Selects between Centigrade ( C) and Fahrenheit ( F) D CHANNEL SLIDE SWITCH Designates the remote unit Channel 1, Channel 2 or Channel 3...
  • Page 4: Low Battery Warning

    and reset the main unit after installing batteries. This will ensure easier synchronization between the transmission and reception of signals. 4. Position the remote unit and main unit within effective trans- mission range, which, in usual circumstances, is 20 to 30 meters.
  • Page 5: The Reset Button

    When it is time to replace batteries, the low-battery indicator will show up when the corresponding channel is selected. The battery level of the main unit will be shown on the indoor temperature when it is running low. HOW TO USE THE TABLE STAND OR WALL MOUNTING The main unit has a removable table stand, which when installed, can support the unit on a flat surface.
  • Page 6: Temperature Trend

    If no signals are received, blanks "----" will be displayed and the kinetic wave icon will show " ". Press [CHANNEL] and [MEMORY] simultaneously to enforce another search for about 30 seconds. This is useful in synchronizing the transmission and reception of the remote and main units.
  • Page 7: Disconnected Signals

    NOTE ON C AND F The unit of temperature display is selected with the C/ F slide switch. Select C for Centigrade or F for Fahrenheit. Note that the remote temperature display on the main unit is dominated by the selection on the C/ F slide switch of the main unit.
  • Page 8: About Radio Reception

    CALENDAR CLOCK DISPLAY MODES The RMR182 supports four display modes in the sequence of: MODE 1. Local Time Hour, Minute, Second ---------------------------- Day, Month MODE 2. Local Time Hour, Minute, Weekday ------------------------------- Day, Month MODE 3. Local Time / Second Time-Zone Time...
  • Page 9: How To Stop An Alarm

    RMR182_EN button HOW TO SET AND ARM THE ALARMS The RMR182 has two alarms, ALARM 1 and ALARM 2. They can be invoked together or independently. To set an alarm: 1. Press [( )] once to select ALARM 1 or again to select ALARM ( •...
  • Page 10 When the alarm goes off the sound which will gradually increase in volume and repeating speed will be turned on for about 2 minutes unless the [( )] or [AL ON/OFF] button is pressed to mute the ( • ) alarm.
  • Page 11: Specifications

    SPECIFICATIONS Temperature Measurement Main unit Indoor Temperature measurement Displayed IN temperature range : -9.9 C to +70.0 C 14.2 F to 158.0 F Proposed operating range : -5.0 C to +50.0 C 23.0 F to 122.0 F Temperature resolution : 0.1 C 0.2 F Remote Temperature measurement Displayed OUT temperature range : -50.0 C to +70.0 C...
  • Page 12: About Oregon Scientific

    We hope you will find all the information you need on our website, however if you'd like to contact the Oregon Scientific Customer Care department directly, please visit www2.oregonscientific.com/ service/support Call 949-608-2848 in the US.
  • Page 13: Ec Declaration Of Conformity

    EC-DECLARATION OF CONFORMITY This product contains the approved transmitter module that com- plies with the essential requirements of Article 3 of the R&TTE 1999 / 5 / EC Directive, if used as intended and the following standards have been applied: Safety of information technology equipment (Article 3.1.a of the R&TTE Directive) Applied Standard...
  • Page 14 © 2004 Oregon Scientific. All rights reserved. 086-002217-141 RMR182_EN 8/16/04, 2:58 PM...
  • Page 15 Multi-Channel In-Out Thermometer with Cable Free Sensor and RF Clock Model : RMR182 User Manual RMR182_EN 8/16/04, 2:58 PM...

Table of Contents