Connection Tubing; Drainage Hose; Tubing Hole; 91Wwlmlm Mounting Plate - GE AE1CDIOAM Owner's Manual And Installation Instructions

Mini split system
Table of Contents

Advertisement

Available languages

Available languages

Installation
Instructions
INSTALLATION
[] INSTALL THE MOUNTING
PLATE
• Always mount the mounting
plate horizontally.
• Attach the mounting
plate at the selected location
with screws supplied with the unit.
• Be sure that the mounting
plate has been
attached
firmly enough to withstand
the weight
of on adult of 130 Ibs. Also, the weight should be
evenly shored by each screw.
171INSTALL THE TUBING HOLE
• Make the tubing hole in the wall at o slight
downward
slant to the outdoor side.
3"fromright
edge to center of
right t ubing hole
f
\
Hole is2"diameter for1OK and 14K BTU
l_A''from bottom
models a nd 2_'' diameter for
edge to center of
20KBTU models,
righttubing hole
• To let water drain and prevent damage to wiring
and tubing, insert o 2V/' plastic pipe, cut to o
length equal to the wall depth. Insert the tubing
and wiring through the pipe.
• Copper tubing should be copped until ready to
install flare fitting, to prevent contamination.
[_] INSTALL THE DRAINAGE HOSE
• For good drainage,
the drain hose should be
placed at o downward
slant.
• Do not wrench or bend the drain hose or allow
it to contact standing water.
• The extended drainage tube in the room should
be wrapped
with the insulating
materials.
\
X
X
Flooded
I_ INSTALL THE CONNECTION
TUBING
• Connect the copper tubing with the relevant union
tubes of the indoor unit and tighten the flare nut
of the connection
tubes.
NOTE: Be careful when bending the connection
tubes to ovoid damaging
them.
1. Align the center of the tube flere with the relevant
velve.
2. Screw in the flare nut by hand end then tighten
the nut with spanner and torque wrench. See the
table below for the correct torque.
3. Connecting
tube specifications
ere shown below:
10,000/14,00020,000
Specifications
BTU Units BTU Units
Design Length
20 ft.
26.2 ft.
Extra Refrigerant Charge
0.16 oz./ft.
0.54 oz./ft.
Per Ft.AboveDesignLength
Outer Diameter Liquid Pipe
1/4"
3/8"
Outer Diameter Gas Pipe
1/2"
5/8"
Max. Distance Height
33 ft.
33 ft.
Max. Distance Length
68 ft.
98 ft.
NOTE: Exceeding tightening
torque
will damage
the copper tubing.
Tightening torque table
Tubing OD
1/4"
3/8"
1/2"
5/8"
Tightening
torque(in./Ib.)
140-170
270-310
440-480
530-570
Flarenut
Joint
Spanner
uewrench
11

Advertisement

Table of Contents
loading

Table of Contents