Installation
Instructions
Read these instructions
completely
and carefully; then follow
step by step.
SELECT THE BEST LOCATION
r_ INDOOR
UNIT
• Do not allow ang heat or steam near the unit.
• Select a location where there are no obstacles
in front of the unit.
• Make sure that condensate
drainage can be
convenientlg
routed awag.
• Do not install near a doorwag.
• Ensure that the space around the left and right
of the unit is more than 6". The unit should be
installed as high on the wall as possible, allowing
a minimum
of 6" from ceiling.
• Use a stud finder to locate studs for mounting
and
to prevent unnecessarg
damage to the wall.
• Install on studs and in a location from which
the condensation
water can be drained out
convenientlg
and that permits easg connection
with the outdoor
unit.
• Do not cover the inlet and outlet so that the
outflow
air can reach all parts of the room.
• Install in a location that is strong enough to
withstand
the full weight and vibration
of the unit.
• Be sure that the installation
conforms to the
installation
dimension diagram.
• Leave enough space to allow access for routine
maintenance.
The height of the installed location
should be 79" or more awag from the floor.
• Install in a location that is 3 ft. or more awag from
other electrical
appliances,
such as televisions and
audio devices.
• Select a location that gives gou easg access to
remove and clean the filter.
Morethan6"
More
f,
_ ,
,
....
More
Morethan79"
[]OUTDOOR
UNIT
• If an awning
is built over the unit to prevent direct
sunlight or rain exposure, make sure that heat
radiation
from the condenser
is not restricted.
• Ensure that the space around the back and sides
is more than 12". The front of the unit should have
more than 79" of space.
H
Morethan12"
Theplatformmust
support a minimumof
Morethan79"
200Ibs.SeeInstallation
Dimensions f ormounting
holespacing.
• Install in a location that is strong enough to permit
safe installation
and to withstand
the full weight
and vibration
of the unit.
• Construct
and anchor o strong and level mounting
base or pod for the outdoor
unit.
• Anchor the outdoor
unit through
its four mounts,
using bolts.
• Select o location from which noise and outflow
air emitted bg the unit will not inconvenience
neighbors.
• In humid locations, the unit mog sweat and
condensation
(water) mag drip from it. Take this
into consideration
when choosing the location.
• Select a location that has sufficient
ventilation.
• Do not cover the inlet and outlet.
• Install unit owog from flammable
gas or corrosive
gas leaks.
• Be sure the installation
conforms to the installation
dimension
diagram.
• Rooftop
Installations:
If the outdoor
unit is installed on a roof structure,
be sure to level the unit. Ensure the roof structure
and anchoring
method are adequate
for the unit
location. Consult local codes regarding
rooftop
mounting.
10