INSTALLATION
STEP
6
Install the Door Control
Locate the doorcontrolwithin sight of door, at a minimum
height of 5 feet (1.5 m) where small children cannotreach,
away from movingparts of door and door hardware. If installing
into drywall, drill 5/32" holes and usethe anchorsprovided. For
pre-wired installations (as in new home construction),it may
be mountedto a single gang box (Figure 2).
1. Strip 7/16" (11 mm) of insulation from one end of bell wire and
connect to the two screw terminals on the back of the door
control by color: white wire to 2 and white/red wire to the 1.
2. Removecover by gently prying at slot in top of the cover with a
small flat head screwdriver. Fastenwith 6ABx1-1/4" self-tapping
screws (drywall installation) or 6-32x1" machine screws
(into gang box) as follows:
• Install bottom screw, allowing 1/8" (3 mm) to protrude above
wall surface.
• Position the bottom of the door control on the screw head
and slide down to secure. Adjust screw for snug fit.
• Drill and install top screw with care to avoid cracking plastic
housing. Do not overtighten.
• Insert top tabs and snap on cover.
3. (For standard installation only) Run bell wire up wall and
across ceiling to motor unit. Use insulated staples to secure
wire in several places. Do not pierce wire with a staple, creating
a short or open circuit.
4. Strip 7/16" (11 mm) of insulation from end of bell wire. Connect
bell wire to the quick-connect terminals as follows: white to
white and white/red to red.
5. Position the antenna wire as shown.
6. Use tacks or staples to permanently attach entrapment warning
label to wall near the door control, and manual release/safety
reversetest label in a prominent location on inside of garage
door.
NOTE:DO NOT connect power and operate opener at this time.
The trolley will travel to the furl open position but will not return
Door Control Connections
Strip wire 7/16" (11 mm)
417/16"(11
rnm)
To prevent possible SERIOUSINJURYor DEATHfrom
electrocution:
• DisconnectALL electric and battery power BEFORE
performing ANY service or maintenance.
• Connect ONLYto 24 VOLTlow voltage wires.
To prevent possible SERIOUSINJURYor DEATHfrom a closing
garage door:
• Install the door control within sight of garage door, out of
reachof children at a minimum height of 5 feet (1.5 m), and
away from ALL moving parts of door.
• NEVERpermit children to operate or play with door control
push buttons or remote controls.
• Activate door ONLYwhen it can be seen clearly, is properly
adjusted, and there are no obstructions to door travel.
• ALWAYS keepgarage door in sight until completely closed.
NEVERpermit anyone to cross path of closing garage door.
HARDWARESHOWN ACTUALSIZE
(std installation)
to the close position until the sensor beam is connected and
properly aligned.
_Top
,,
_1+
--
+1 )Mounting
_ell
II
I I Hole
Wire
f:1
It
'
....
Terminal
II 1","
I screws
I_
Bottom
....
Mounting
(BACK VIEW)
Hole
Insulated
Staples
(pre-wired)
Drywall Anchors
Figure 1
Figure2
REMOVE& REPLACECOVER
PRE-WIRED INSTALLATION
To Replace
Insert Top
Ta__
_
_.
Push Bar Cover
I Wire
To release or insert wire,
)ush in tab with screwdriver tip
Red White Grey