Voltage And Circuit Protection; Extension Cords; Lubrication And Oil - DeVilbiss 250E20AD Generator User Manual

Oil lubricated single stage portable air compressor
Table of Contents

Advertisement

Voltage andCircuitProtection
Refer to your Parts Manual for voltage and circuit protection
requirements of your compressor. Use only a fuse or circuit
breaker that is the same rating as the branch circuit the air
compressor is operated on. If the compressor is connected to
a circuit protected by fuses, use only dual element time delay
fuses, as noted in the Parts Manual.
rl_mJ
dIs] _1
Certain air compressors can be converted from
120V to 240V operation. When converting
an
air compressor
to
240V
operation,
the
attached
three-prong
120V
=ord
assembly
must be replaced
with a three-pronged
240V
cord assembly that can be purchased through
an Authorized
Warranty
Service
Center.
To
locate an Authorized Warranty Service Center
nearest you, call us at 1-800-888-2468,
Ext.
2, then 2.
Some models have a dual voltage motor, 120 and 240 volt.
They are wired for 120 volt but can be converted to 240 volt
operation. Instructions for connecting the motor for operation
at 240 volt can be found printed on the label attached to the
side of the motor.
PM[s_.4!l d[*] _1
Certain air compressor models san be operated
on a 15 amp circuit If:
1. Voltage supply to circuit is normal.
2. Circuit is not used to supply any other
electrical
needs (lights, appliances,
etc.)
3. Extension cords comply
with specifications
in this manual.
4. Circuit is equipped with a 15 amp circuit
breaker or 15 amp time delay fuse.
Extension Cords
To avoid voltage drop and power loss to the motor, and to
prevent overheating, use extra air hose instead of an exten-
sion cord.
If an extension cord must be used:
• use only a 3-wire extension cord that has a 3-blade ground-
ing plug and s 3-slot receptacle that will accept the plug on
the extension cord.
• make sure the extension cord is in good condition.
• the extension cord should be no longer than 50 feet.
• the minimum wire size is 12 gauge (AWG). (Wire size in-
creases as gauge number decreases. 10 AWG and 8 AWG
may also be used. DO NOT USE 14 AWG or 16 AWG.)
Lubrication and Oil
Place unit on a level surface. Remove oil fill plug and slowly
add a compressor oil such as Castrol Heavy Duty 30 weight
until it is even with the top of the oil fill hole. (It must not be
allowed to be lower than 3/8" -- 6 threads down -- from the
top at any time.) When filling the crankcase, the oil flows very
slowly into the pump. If the oil is added too quickly, it will
overflow and appear to be full. Crankcase off capacity is 16
fluid ounces. Replace oil fill plug.
NOTE
Drain and refill the compressor pump crank-
case after the first 100 hours of operation.
GROUNDING
INSTRUCTIONS
RISK OF ELECTRICAL SHOCI(J In the event of a
short circuit,
grounding
reduces the risk of
shock by providing
an escape
wire for the
electric current.
This air compressor must be
properly grounded.
The air compressor is equipped with a cord having a ground-
ing wire with an appropriate grounding plug. The plug must be
used with an outlet that has been installed and grounded in
accordance with all local codes and ordinances. The outlet
must have the same configuration as the plug. See illustra-
tion. DO NOT USE AN ADAPTER.
Inspect the plug and cord before each use. Do not use if
there are signs of damage.
IMPROPER GROUNDING CAN RESULT IN ELEC-
TRICAL SHOCK.
Do not modify the plug that has been provided. If it does not
fit the available outlet, the correct outlet should be installed
by a qualified electrician.
If repairingor replacing cord or plug, the grounding wire must
be kept separate from the current-carrying
wires. Never
connect the grounding wire to a flat blade plug terminal. The
grounding wire has insulation with an outer surface that is
green - with or without yellow stripes.
If these grounding instructions
are not completely under-
stood, or if in doubt as to whether the compressor is properly
grounded, have the installation checked by a qualified elec-
trician.
Lf_[tT...tl]ll[o]_I
Multi-Viscosity motor oils, like 10W30, shouldnot be
used in an air cornpressor. They leave carbon depo6-
its on critical components, thus reducing porfor-
manse and compressor life.
Como_
are shim)ed without oil. Asman amount
of oil may be present in the pump upon receipt ofthe
air compressor.
This is duets planttssting
and does
not meanthat
the pump €ontains
oil. Do not attempt
to eperatethis
air compresssrwithout
first adding oil
to the crankcase.
Sedous
damage
can result from
even limited operation unless filled with oil and bro-
ken in co_ectly.
Make sure to closely follow initial
start-up procedures.
7
120 Volt aodals
24O VMt Models
Whttm