*A circuit breaker is preferred. Use only a fuse or circuit breaker that is the same rating as the branch circuit the air compressor is operated on. If the air compressor is connected to a circuit protected by fuses, use quick acting fuses.
(income producing) are covered by a 90 day warranty. DeVilbiss Air Power will repair or replace, at DeVilbiss's option, products or components which have failed within the warranty period. Repair or replacement, and service calls on 60 and 80 gallon air compressors, will be handled by Authorized Warranty Service Centers and will be scheduled and serviced according to the normal work flow and business hours at the service center location, and depending on the availability of replacement parts.
OUS OVERHEATING AND COULD CAUSE FIRE. UNATTENDED OPERATION OF THIS PROD- UCT COULD RESULT IN PERSONAL INJURY OR PROPERTY DAMAGE. YOUR AIR COMPRESSOR IS POWERED BY RISK OF ELECTRICITY. ELECTRICAL SHOCK CALLY POWERED DEVICE, IF IT IS NOT USED PROPERLY SHOCK.
WHAT CAN HAPPEN COMPRESSOR FALL All DeVilbiss Air Power manufactured air compressors should be operated on not more than a 50% duty cycle. This means an air compressor that pumps more than 50% of one hour, is considered misuse, because the air compressor is undersized for the required air demand.
Location of the Air Compressor Your compressor comes to you completely assembled and ready for use. Operate the air compressor in a dry, clean, cool and well ventilated area. The air compressor pump and case are designed to allow for proper cooling.
120 Volt Models 120 Volts, 15 Amps OPERATING PROCEDURES 1. Before plugging in the air compressor, set the adjust- able pressure valve to "10" PSI. Make sure the "ON/ OFF" switch is in the "OFF" position. 2. Connect the air tool or accessory to the air hose.
10 P.S.I. STORAGE 3. Protect the electrical cord and air hose from damage by winding them loosely around the air compressor. 4. Store the air compressor in a clean and dry location. 8 — ENG...
ON/OFF SWITCH COMPRESSOR ASSEMBLY PARTS AVAILABLE FOR THIS UNIT DESCRIPTION Safety Valve ...TIA-4150 Drain Valve ...SS-2707 Pressure Valve Assembly...CAC-4324 Outlet Tube ...CAC-1289 Connecting Rod Kit ...KK-4926 Fastener Kit ...KK-4929 Isolator Kit ...KK-4930 PARTS LIST PRESSURE VALVE ASSEMBLY PART NUMBER 9 — ENG OUTLET TUBE SAFETY VALVE AIR TANK...
TROUBLESHOOTING GUIDE VOLTAGE SOURCES, MOVING PARTS OR COMPRESSED AIR SOURCES ARE EXPOSED WHEN REPAIRING THE COMPRESSOR. PERSONAL INJURY CAN OCCUR. UNPLUG THE COMPRESSOR BEFORE ATTEMPTING ANY REPAIRS. PROBLEM CAUSE Air Leaks Hose fitting loose. Prolonged excessive use of air. Compressor is not delivering enough air.
OWNERS MANUAL FOR MODEL NO. FA752-2 FAC752-2 (For Home Use Only) Retain Original Sales Receipt as Proof of Purchase for Warranty Repair Work. DeVilbiss Company Air Power • 213 Industrial Dr. • Jackson, TN 38301-9615 Attach Sales Receipt Here.