Removing The Ghost Storage System; Returning The Failed Disk; Replacing The Raid Controller; Verifying Component Failure - HP StoreVirtual 4000 User Manual

10.0 hp lefthand storage user guide (ax696-96202, november 2012)
Hide thumbs Also See for StoreVirtual 4000:
Table of Contents

Advertisement

1.
Right-click the management group, and select Edit Management Group.
The current Bandwidth Priority value indicates that each manager in that management group
will use that much bandwidth to transfer data to the repaired storage system. Make a note of
the current value so it can be restored after the data rebuild completes.
2.
Change the bandwidth value as desired, and click OK.

Removing the ghost storage system

You can remove the ghost storage system after the data is rebuilt on the repaired storage system.
Data is rebuilt on the storage system when two conditions are met:
The repaired storage system's disk usage matches the usage of the other storage systems in
the cluster.
The status of the volume and snapshots goes back to Normal.
To remove the ghost storage system:
1.
Right-click the ghost IP address and select Remove from Management Group.
2.
If you have changed the Local Bandwidth Priority of the management group while the data
was being rebuilt, change it back to the original value.
At this point, the disk in the storage system is successfully replaced, the data is fully rebuilt on that
storage system, and the management group configuration (number of managers, quorum, local
bandwidth, and so on) are restored to the original settings.

Returning the failed disk

1.
Contact HP Support for an RA number.
2.
Return the original disks for failure analysis using the prepaid packing slip in the replacement
package. Put the RA number on the package as instructed by HP Support.

Replacing the RAID controller

Before you begin, have the following items ready:
T- 1 0 wrench (stored on the rear of the storage server)
Replacement RAID controller
CAUTION:
discharge (ESD). Use proper anti-static protection at all times:
Keep the replacement component in the ESD bag until needed.
Wear an ESD wrist strap grounded to an unpainted surface of the chassis.
If an ESD wrist strap is unavailable, touch an unpainted surface of the chassis before handling
the component.
Never touch connector pins.

Verifying component failure

Look at the system health LED for the controller cards (2,
there is a problem.
248 Replacing hardware
When handling system components, there is a danger to equipment from electrostatic
Figure 1 12 (page
249)) to determine if

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lefthand storage