Configuring The Hp Storeonce Backup System For Fibre Channel - HP StoreOnce B6000 Configuration Manual

Hp b6000 storeonce backup system linux and unix configuration guide
Hide thumbs Also See for StoreOnce B6000:
Table of Contents

Advertisement

Alias: -
ISID: 4000002a0000
Connections: 1
7.
To create generic devices drivers for the iSCSI target devices, using the following commands:
# update_drv -ai '"scsiclass,08"' sgen
# devfsadm -i iscsi
8.
To verify devices files for the iSCSI target device have been created, use these commands:
# ls
l /dev/scsi/changer
lrwxrwxrwx
../../../devices/iscsi/medium-changer@0000iqn.1986-
03.com.hp%3Astorage.d2d.cr203f18f4.19f71d0c4c694ca8.library1
.robotics0001,0:changer
Here you can see device file c3t1d0 has been created for the changer element.
# ls -l /dev/rmt/*cb
lrwxrwxrwx
/dev/rmt/2cb -> ../../devices/iscsi/tape@0000iqn.1986-03.com.hp%3Astorage
.d2d.cr203f18f4.01a9754150ae013a.library1.drive10001,0:cb

Configuring the HP StoreOnce Backup System for Fibre Channel

For a Switched Fabric Configuration, zone the individual devices to the host concerned using the
virtual device WWNs shown on the product's GUI.
An example of a GUI is shown below; for details of the GUI specific to your product, please refer
to the product's User Guide.
1.
To create generic devices drivers for the iSCSI target devices, using the following commands:
# update_drv -ai '"scsiclass,08"' sgen
# cfgadm -al
30
Solaris (x86 and SPARC)
1 root
root
1 root
root
139 Jan
2 09:51 c3t1d0 ->
116 Apr 18 14:51

Advertisement

Table of Contents
loading

Table of Contents