Configuring The Hp Storeonce Backup System For Fibre Channel - HP StoreOnce B6000 Configuration Manual

Hp b6000 storeonce backup system linux and unix configuration guide
Hide thumbs Also See for StoreOnce B6000:
Table of Contents

Advertisement

# kcmodule
* The automatic 'backup' configuration has been updated.
Module
schgr
stape
HP-UX 1 1i V3
# kcmodule
* The automatic 'backup' configuration has been updated.
Module
schgr
stape
eschgr
estape
10. To create device files for the target devices, type the following:
# insf
1 1. To display the device files associated with the operational target devices, type:
# ioscan
Class I H/W Path Driver S/W State H/W Type Description
==========================================================================
iscsi
ext_bus 8 255/0/0.0
Interface
target 10 255/0/0.0.0
tape
/dev/rmt/c8t0d0BEST
/dev/rmt/c8t0d0BESTb
ext_bus 9 255/0/2.0
Interface
target 11 255/0/2.0.0
autoch
In this example the tape drives device files are:
/dev/rmt/1m
/dev/rmt/1mb
/dev/rmt/1mn
/dev/rmt/1mnb
/dev/rmt/c8t0d0BEST
/dev/rmt/c8t0d0BESTb
/dev/rmt/c8t0d0BESTn
/dev/rmt/c8t0d0BESTnb
And the autochanger device file is:
/dev/rac/c9t0d0

Configuring the HP StoreOnce Backup System for Fibre Channel

For a Switched Fabric Configuration, zone the individual devices to the host concerned using the
virtual device WWNs shown on the product's GUI.
B stape=static schgr=static
State
(now)
static
(next boot)
static
(now)
static
(next boot)
static
h
B stape=static estape=static schgr=static eschgr=static
State
(now)
static
(next boot)
static
(now)
static
(next boot)
static
(now)
static
(next boot)
static
(now)
static
(next boot)
static
H 255
fnH 255
0 255/0
iscsi
iscsial CLAIMED
tgt
1 255/0/0.0.0.0 stape
/dev/rmt/1m
/dev/rmt/c8t0d0BESTn
/dev/rmt/1mb
/dev/rmt/c8t0d0BESTnb
iscsial CLAIMED
tgt
0 255/0/2.0.0.0 schgr
/dev/rac/c9t0d0
Cause
best
explicit
best
explicit
Cause
best
explicit
best
explicit
best
explicit
best
explicit
CLAIMED
VIRTBUS
iSCSI Virtual Node
INTERFACE iSCSI-SCSI Protocol
CLAIMED
DEVICE
CLAIMED
DEVICE
HP
/dev/rmt/1mn
/dev/rmt/1mnb
INTERFACE iSCSI-SCSI Protocol
CLAIMED
DEVICE
CLAIMED
DEVICE
HP
AT&T, best density available
Berkeley, best density available
AT&T, no rewind, best density available
Berkeley, no rewind, best density available
AT&T, best density available
Berkeley, best density available
AT&T, best density available
Berkeley, no rewind, best density available
Configuring the HP StoreOnce Backup System for Fibre Channel
Ultrium 3-SCSI
MSL G3 Series
21

Advertisement

Table of Contents
loading