Configuration And Status Errors - HP StorageWorks XP10000 - Disk Array Administrator's Manual

Hp storageworks xp virtualization adapter administrator guide (5697-0216, october 2009)
Hide thumbs Also See for StorageWorks XP10000 - Disk Array:
Table of Contents

Advertisement

[XP Virtualization Adapter][Time]: ["Command line"] : popen : "system error message"
Cause - An execution of Command line has failed via popen() call.
Action to be taken - Confirm if XP RAID Manager is installed, or the path of Command line is
correct, or %HORCMROOT% ENV has being set, or make action by referring to system error
message.
[XP Virtualization Adapter][Time]: [ ] : malloc : "system error message"
Cause - Could not retain the memory for executing a XP Virtualization Adapter.
Action to be taken - Increase the capacity of virtual memory of the whole system or terminate un-
necessary programs or Daemon processes running simultaneously.
[XP Virtualization Adapter][Time]: [ ] : "Command line" failed with RC=XXX.
Cause - The XP RAID Manager command Command line has failed with RC=XXX.
Action to be taken - Remove the cause of the error after confirming the XP RAID Manager error
code and command error log messages output in this log file as shown in the example below:
---------------------------------------
COMMAND ERROR : EUserId for HORC[24] : root (0) Thu Jul 17 18:38:55
2008
CMDLINE : pairdisplay -IH -d 64015 9 0 -CLI -l -fwe
18:38:55-41110-14817- ERROR:cm_sndrcv[rc < 0 from HORCM]
18:38:55-4c5e8-14817- Could not find a group on configuration file for
this LDEV.(Port# ?,Seq# 64015,LDEV# 9,mun# 0)
18:38:55-51feb-14817- [pairdisplay][exit(239)]
[EX_ENOGRP] No such group
[Cause ]:The group name which was designated or the device name doesn't
exist in the configuration file,or the network address for remote com-
munication doesn't exist.
[Action]:Please confirm if the group name exists in the configuration
file of the local and remote host.
---------------------------------------

Configuration and status errors

[XP Virtualization Adapter][Time]: [disarray_exe] : Unknown PWWN.
Cause - Could not find the Port WWN in the output of pairdisplay −fw command via dis-
coverArrays.
Action to be taken - Confirm if XP RAID Manager is a version supported by XP Virtualization Ad-
apter.
[XP Virtualization Adapter][Time]: [dislun_exe] : invalid arrayId (- ).
Cause - A parameter in XML (discoverLuns) was entered from SRM to the XP Virtualization Adapter,
but it could not be found correct array ID.
Action to be taken - Confirm if SRM has passed an array ID parameter in XML (discoverLuns) from
own SRM log message
[XP Virtualization Adapter][Time]: [dislun_exe] : Unknown PWWN.
Cause - Could not find the Port WWN in the output of pairdisplay −fw command via dis-
coverLuns.
Action to be taken - Confirm if XP RAID Manager is a version supported by XP Virtualization Ad-
apter.
XP Virtualization Adapter Administrator Guide