INSTALLATION

RIGID PIPE VENTING - VERTICAL TERMINATIONS

FOR BOTH RESIDENTIAL & MANUFACTURED HOMES/MOBILE HOMES
Vertical Terminations
with Co-linear Flex System
The shaded area in the diagram shows the allowable vertical
terminations installed in a masonry chimney. All vertical vent instal-
lations require the Vent Restrictor to be set to 1-1/4" (32mm) open.
Straight Vertical Terminations
If using a Rigid Pipe Venting Sys-
tem a rigid pipe adaptor #640-994
is required.
Rigid Pipe
Adapter
14
WARNING:
Do not combine venting components from
different venting systems.
However use of the the AstroCap
Riser is acceptable with all systems.
This product has been evaluated by Intertek for
using a Rigid Pipe Adaptor in conjunction with
Duravent Direct-Vent GS, Selkirk Direct-Temp,
Ameri Vent Direct venting and Security Secure
Vent systems. Use of these systems with the
Rigid Pipe adaptor is deemed acceptable
and does not affect the Intertek WHI listing of
components.
When using Rigid Vent other than
Simpson Dura-Vent, 3 screws must be
used to secure rigid pipe to adaptor.
The FPI AstroCap
TM
and FPI Riser Vent terminal are
certifi ed for installations using FPI venting systems
as well as Simpson Dura-Vent
®
American Metal Products Ameri Vent Direct Vent,
®
Security Secure Vent
, Selkirk Direct-Temp. Astro-
TM
Cap
is a proprietary trademark of FPI Fireplace
Products International Ltd. Dura-Vent® and Direct
Vent GS are registered and/or proprietary trademarks
of Simpson Dura-Vent Co. Inc.
Vent restriction is required for
certain venting installations,
see the diagrams in "Venting
Arrangment" section to deter-
mine if they are required for your
installation.
To set the Vent restriction as
indicated in the diagram, simply
loosen the screws and push the
vent restrictor plate to the correct
position. Tighten the screws.
Vertical Terminations
using Rigid Piping Systems
The shaded areas in the two diagrams below show all allowable
combinations of straight vertical and offset to vertical runs with
vertical terminations. Maximum one 90
offset to vertical vent installations require Vent Restrictor to be set to
1-1/4" (32mm) open. If the vent is ENCLOSED in a chase (min. size
9" x 9") maintain a 1-1/4" (32mm) clearance to combustibles.
Offset to Vertical Terminations
TM
and FPI
Direct Vent GS,
Vent Restrictor Position
®
U37-1 Regency
ULTIMATE Rear Vent Direct Vent Freestanding Gas Stove