Adjusting the Dehumidi_ca_bn
Setpo&t
Dehum
Terminal:
Ifa MISC terminal
is selected
for DEHUM
operation
(see page
10.2), then the thermostat
will provide
power to this terminal
when the humidity
in the building
is above the setpoint
you have chosen.
See page 10.6 for detailed
programming
instructions.
To utilize this
feature
your HVAC unit must be equipped
with a DEHUM
terminal.
Cool to Dehumidify:
If the thermostat
is programmed
for Cool to
Dehumidify
operation,
then the thermostat
will energize
the cooling
system any time the humidity
in the building
is above
the setpoint
you
have chosen.
See page 10.4 for detailed
programming
instructions.
In each case, when the indoor
humidity
falls below
the setpoint
you
have selected,
Cool to Dehumidify
and the MISC terminal
will be
de-energized.
The value for this setpoint
ranges from 25% to 99%.
NOTE;
Due to variations
in environmental
conditions,
it is not always
possible to achieve the desired humidification
or dehumidification
setpoin_
HUMIDfTY
@
Press
the HUMIDITY
button
to enter
the
Humidification
NOTE:
Each
step # is located
at
Setup
screens,
rob.
_he top right
corner
of the
display
for easy
reference
MOD__._J
Press the MODE button once
,j
_P
Set_A_
Press
Pressthe HUMIDITYbuttonto leave the Humidity
Controlscreens(if no buttonsare pressed,the display
will leavethe HumidityControl screensafter 30seconds).
Dehumidification
Notes:
Press
the ,;:ii,_ button
to set the
dehumidification
setpoint
to 99% for no dehumidification
operation.
This will Iockout
Advanced
Setup
steps
9 and
10 (see
page
10.4).
You
canr_ot
set
the
(leh_rrli(liry
setpolnt
ar_y
lower
than
the
h_rrli(liry
setpo_nt
a
5°/,
differential
is
forced
betweerl
the
hurrlidify
and
dehumidify
setpoints
Page 10.3