Carrier 33CSSP3-FC Owner's Manual
Hide thumbs Also See for 33CSSP3-FC:

Advertisement

Quick Links

Owner's Manual
Downloaded from
ManualsNet.com
search engine

Advertisement

Table of Contents
loading

Summary of Contents for Carrier 33CSSP3-FC

  • Page 1 Owner’s Manual Downloaded from ManualsNet.com search engine...
  • Page 2: Table Of Contents

    P/N 33CSSP3-FC © Copyright 2014, All Rights Reserved Downloaded from ManualsNet.com search engine...
  • Page 3: Front Panel

    Front Panel COOL AUTO HEAT Mode 1 Liquid Crystal Display with Thermoglow 2 Up/Down Buttons 3 Mode Button 4 Fan/Override Button 5 Heat or Cool Indicator Heat = Red, Cool = Green Downloaded from ManualsNet.com search engine...
  • Page 4: Display

    Display UTSIDE 1 Mode Indicators - Page 7-10 Selects the operational mode of the equipment. HEAT - Indicates the heating mode. COOL - Indicates the cooling mode. AUTO - Indicates the system will automatically changeover between heat and cool modes as the temperature varies. PROGRAM ON - Indicates the time period program is enabled to run.
  • Page 5 Display UTSIDE 5 Override icon - Page 12 & 21 Indicates the program is currently being overriden for up to six hours. 6 Occupied & Unoccupied icons - Pages 13-16 Indicates the program number: Occupied 1, 2, 3, or Unoccupied. 7 Setup icons - Pages 18-22 Indicates the thermostat is in the advanced setup mode.
  • Page 6 Display UTSIDE 9 Start & Stop icon - Page 14 & 16 Appear when programming occupied time periods. 10 Locked icons - Pages 30 Indicates keypad has been locked. 11 Outside icons - Pages 21-31 Indicates the temperature displayed is from the optional outside sensor. Downloaded from ManualsNet.com search engine...
  • Page 7: Quick Start Set The Clock And Go

    Quick Start Set the Clock and Go MODE Press the MODE and FAN buttons at the same time for two seconds to enter Setup screens. During Setup and Programming: Pressing Setting the Clock the UP or DOWN button Tip: To change hours will modify the flashing quickly, press and hold selection.
  • Page 8: Selecting The Heat Or Cool Mode

    Selecting the Heat or Cool Mode 4-Pipe Operation Select Mode by Pressing the MODE Button Heating Only The HEAT setting indicates the temperature that the room has to fall to before the heat- ing source will turn on to heat the room. Press MODE Cooling Only...
  • Page 9 Selecting the Heat or Cool Mode 2-Pipe Operation Heat Only Step #6 = 1 in the Advanced Setup section, page 19. Heating Only The HEAT setting indicates the temperature that the room has to fall to before the heating source will turn on to heat the room. Press MODE Time Schedule for Heating or Cooling...
  • Page 10 Selecting the Heat or Cool Mode 2-Pipe Operation Cool Only Step #6 = 2 in the Advanced Setup section, page 19. Cooling Only The COOL setting indicates the temperature that the room has to rise to before the cooling source will turn on to cool the room. Press MODE Time Schedule for Heating or Cooling...
  • Page 11 Selecting the Heat or Cool Mode 2-Pipe Operation Heating and/or Cooling Step #6 = 3 in Advanced Setup (page 19), and a changeover sensor is used. Step #6 = 4 or 5 in Advanced Setup (page 19). Operation is the same as a 4-pipe system (page 7). HEAT indicates the temperature that the room has to fall to before the heating source ener- gizes.
  • Page 12: Basic Operation

    Basic Operation Selecting Your Desired Temperature (adjusting the setpoints) AUTO OR PROGRAM MODE Pressing the UP or DOWN button in Auto or Program mode will adjust both the heat and cool set temperatures simultaneously. Adjust the desired set temperature with the buttons Fan Operation Press...
  • Page 13: Overriding The Daily Schedule

    Basic Operation Overriding the Daily Schedule Pressing and holding the FAN button for 5 seconds may be used to interrupt the normal time schedule programming of the thermostat. The override feature may only be used when the thermostat is running the time schedule, in Program On mode. Unoccupied Operation - During programmed, unoccupied periods pressing and holding the FAN button for 5 seconds will temporarily force the thermostat into Occupied 1 comfort settings for one to six hours (step #13, page 21).
  • Page 14: Programming Occupied / Unoccupied

    Programming Occupied & Unoccupied Periods Press the MODE button. While holding MODE, press MODE the UP button for two seconds to enter time period programming. Select the maximum # of occupied periods to be used on any one day. Typically, most installations use only Occupied 1.
  • Page 15 Programming Occupied & Unoccupied Periods Adjust the heating setpoint for Unoccupied periods. (OF, 35˚- 99˚) Press MODE Select day of the week for Occupied 1. (Mo - Su) Press MODE Adjust the start time for Occupied 1. Press MODE Adjust the stop time for Occupied 1.
  • Page 16 Programming Occupied & Unoccupied Periods The copy command becomes available after the maximum # of occupied periods are programmed in a day. This example uses 1 as the maximum occupied periods ever programmed in one day. Select Yes or No to copy the previous day’s program to this day.
  • Page 17 Programming Occupied & Unoccupied Periods Adjust the stop time for Occupied 1. Select Occupied 1 to run on this day (On), or not to run this day (Off). Press MODE Select Yes or No to copy the pre- vious day’s program to this day. If Yes is selected: If No is selected:...
  • Page 18 Programming Occupied & Unoccupied Periods PROGRAMMING NOTES You will be prompted to enter both heat and cool setpoints even if the thermostat is configured for heat only, or cool only. • If only 1 Occupied period is selected, the Occupied 2 & 3 steps will be skipped. Further, if only 2 occupieds are selected, the Occupied 3 steps will be skipped. • Heat & Cool setpoints for Occupied 1 are the same for each day. Heat &...
  • Page 19: Advanced Setup

    Advanced Setup MODE Press the MODE and FAN NOTE: Each step # is located at the top right corner of the buttons at the same time display for easy reference. for 10 seconds to enter Advanced Setup screens. Adjust the time of day. Tip: To change hours quickly, press and hold the FAN Setup...
  • Page 20 Advanced Setup Select display operation: Setup 1 = Single Setpoint 2 = Dual Setpoint See page 32 Note: When Single Setpoint is selected, the heating or cooling setpoint will always be displayed. To display the room temperature, Press press and hold the MODE button for two seconds. The degree icon will blink when the large number is displaying room temperature and will remain MODE solid when displaying the heating or cooling setpoint.
  • Page 21 Advanced Setup Select operation when fan is in the Auto mode: Setup On = continuous low speed fan AUTO Off = only energize during a heating or cooling cycle. Press MODE See Page 28, Note #2 Adjust the deadband Setup for the 1st stage (1˚- 6˚) See page 25...
  • Page 22 Advanced Setup Select thermostat Setup operation in degrees Fahrenheit or Celsius. Press MODE Sensor Reading Select sensor operation: Setup On - read only Duct sensor Press OUTSIDE Off - control to Duct sensor MODE Adjust the amount of time Setup override wil be active during Override the unoccupied time period.
  • Page 23 Advanced Setup Occupied Select Dry Contact operation: Setup occupied Occupied - the thermostat will enter the Occupied mode when the Dry Contact is closed. Unoc- Unoccupied -the thermostat cupied will enter the Unoccupied mode when the Dry Contact is closed. Press MODE Step #16 only appears if step #15 = Unoccupied.
  • Page 24 Advanced Setup Step# Description Range Time of Day 24 hour 12:00 am Day of the Week Mo - Su Display Blanking On / Off Single or Dual Setpoint 1 / 2 2- or 4-Pipe System 2 / 4 2-Pipe System Operation 1 - 5 Fan Auto Operation On / Off...
  • Page 25: About Advanced Features & Operation

    About Advanced Features & Operation CALIBRATION - Under normal circumstances it will not be necessary to adjust the calibration of the temperature sensor. If calibration is required, please contact a trained HVAC technician to correctly perform the following procedure. Place the thermostat in the OFF mode. MODE Press and hold the MODE button.
  • Page 26 About Advanced Features & Operation DEADBAND OPERATION - Controls one Heat and one Cool stage with a three speed fan (see below). The low speed fan for heat or cool is turned on when: The temperature spread from the setpoint is equal to or greater than: the setpoint plus the 1st stage dead-band (step #8, page 20).
  • Page 27 About Advanced Features & Operation DRY CONTACT SWITCH - This feature allows an external device such as a Central Time Clock, Occupancy Sensor, or a Telephone activated device to force one or more thermostats into an Unoccupied mode (steps #14 and 15, page 21-22).
  • Page 28 About Advanced Features & Operation FACTORY DEFAULTS - If, for any reason, you desire to return all the stored settings back to the factory default settings, follow the instructions below. WARNING: This will reset all Time Period and Advanced Programming to the default settings.
  • Page 29 About Advanced Features & Operation FAN OPERATION - Fan operation is available in four different modes: Fan: When only the fan icon is displayed, this indicates that the fan is in the Auto mode, will only energize during a heating or cooling cycle, and will modulate fan speeds based on temperature demand (see page 25).
  • Page 30 About Advanced Features & Operation ENERGY SAVING SMART FAN - This feature automatically de-energizes the fan during an Unoccupied time period, except when necessary to heat or cool (see page 28). Note: The fan will not de-energize during an Unoccupied time period if it has been programmed for continuous operation (step #7, page 20).
  • Page 31 About Advanced Features & Operation KEYPAD LOCKOUT - To prevent unauthorized use of the thermostat, the front panel buttons may be disabled. To disable, or ‘lock’ the keypad, press and hold the MODE button. While holding the MODE button, press the UP and DOWN buttons together.
  • Page 32 About Advanced Features & Operation OUTSIDE SENSOR - To view an Outside Sensor (step #12, page 21), enter the Advanced Setup by pressing and holding the MODE button. While holding MODE, press the FAN button for 5 seconds to enter Setup screens. Advance to setup step #12 by repeatedly pressing the MODE button.
  • Page 33 About Advanced Features & Operation SINGLE SETPOINT BEHAVIOR - When configured for Single Setpoint operation (step #4, page 19), the degree icon will blink when the large number is displaying room temperature and will remain solid when displaying the heating or cooling setpoint. In the Auto mode the deadband is enforced both above and below the setpoint.
  • Page 34 Printed on recycled paper. P/N 88-1077 Rev. 1 Downloaded from ManualsNet.com search engine...

Table of Contents