Available languages

and short hose an additional
two thirds turn using pliers.
D
Do not overtighten. Damage to
the coupling could result.
4. Attach the short hose to the cold
water faucet. Tighten the
connection by hand until the
coupling is seated on the faucet.
5. Use pliers to tighten the
connection an additional
two thirds turn.
D
Do not overtighten. Damage to
the coupling could result.
6. Attach the "Y" adapter to the short
hose. Tighten the coupling by
hand until it is firmly seated on the
hose.
D
Do not use pliers to tighten plastic
threaded fittings onto plastic or
metal threaded connections.
7. Attach the washer cold water
supply hose to the "Y" connector.
Hand tighten only.
8. Attach the dryer water supply hose
to the other coupling of the "Y"
connector.
Hand tighten only.
9. Tighten only metal-to
metal
couplings on the "Y" connector
10.
%
Attach the right-angle connector
on the water supply hose to the
inlet valve located at the top left of
the dryer.
Check to see that the rubber
washer does not fall out, and is
properly seated in the right angle
connector.
11. Hand tighten the coupling until it
is seated on the connector. Do
not use pliers, hand tighten only.
D
Do not overtighten. Damage to
the coupling could result.
12. Turn on the water faucet.
13. Check for leaks around the "Y"
connector, faucet and all hoses.
Electrical
Connection
Power cord must be connected
by a qualified technician
or a
licensed electrician
only.
Connect
to individual branch
circuit.
Do not use an adapter.
Do not use an extension
cord.
Do not remove ground prong.
For CANADA
Your dryer comes with a power supply
cord, CSA listed in Canada.
The Bosch dryer requires a 4-wire
receptacle.
When installing the receptacle for the
dryer cord, ensure that the power
supply cord is accessible when the
dryer is in the installed position.
The power cord should only be
replaced by a qualified technician or
licensed electrician. If you must replace
the power cord that was originally
supplied with your appliance, the
power cord must meet the following
requirement:
4 wire only
UL and CSA listed
208 - 240 volt rated (minimum)
30 amps
Type SRDT
Five feet long (minimum)
Refer to page 49 for 4 wire installation
instructions.
Additional
grounding
procedure
Some local regulations may
require a separate ground. In such
cases, the required accessory
ground wire, clamp and screw
must be purchased separately.
Contact your local dealer or
customer service for additional
details (see page 32).
Never ground the dryer to plastic
plumbing lines, gas lines or water
pipes.
Grounding
instruction
This appliance must be grounded. In
the event of a malfunction or
breakdown, grounding will reduce the
risk of electric shock by providing a
path of least resistance for the electric
current.