Electrical connection

GROUNDING INSTRUCTIONS
d
WARNING
The dryer must only be connected
to an individual branch circuit via a
socket which has been properly
installed and grounded.
The household electrical voltage must
correspond to the voltage specification
on the dryer (rating plate).
You will find the rating plate on the
inside of the front panel.
Connection specifications as well as
the electrical requirements are
stipulated on the appliance nameplate.
Make sure that:
-
the power cord plug fits into the
socket.
-
the power cord is acceptable for
use in this application.
-
the grounding system is properly
installed.
The power cord may be replaced by a
qualified technician or a licensed
electrician only.
Replacement power cords are available
from Customer Service (see page 26).
Volts
Hertz
Amperes
110-120
60
9
10
All manuals and user guides at all-guides.com

Gas connection

d
WARNING
Explosion hazard!
Use a new AGA or CSA approved
gas supply line.
Install a shut off valve.
Securely tighten all gas
connections.
Do not crush or kink the gas line.
Have a qualified person make sure
gas pressure does not exceed
14 in. W.C./ 3.49 kPa/ 0.506 psig.
(Natural Gas and Propane).
Example of a qualified person
include:
-
licensed heating personnel,
-
authorized gas supplier personnel,
-
authorized service personnel.
Failure to do so can result in
explosion or fire.
Risk of death or injury!
All gas line connections must be
tested for leaks prior to appliance
operation. Apply soapy water to gas
line connections and check for
formation of new bubbles. Bubbles
indicate a leak!
When installing the gas supply to the
gas dryer inlet pipe, do not exceed 26
ft-lb (35 Nm).
d
WARNING
Never use an open flame to test for
gas leaks.
Gas type
This dryer when equipped for use with
NATURAL GAS will employ an orifice
size 46 and will have a gas outlet
pressure of 3.5 in. W.C.
Your dryer must have the correct valve
Watts
for the type of gas in your home. Valve
1080
information is located on the rating
plate behind the door below the port
hole.
If the rating plate information does not
agree with the type of gas available,
contact your dealer or our customer
service team (see page 26).
Gas supply line
1
/
" I.D. pipe is recommended.
2
3
/
" approved tubing is acceptable for
8
lengths under 20 ft (6.1 m) if local
codes and gas supplier permit.
1
Must include
/
" NPT plugged
8
tapping, immediately upstream of the
gas connection.
A shut off valve must be included:
-
USA:
An individual manual shut off valve
must be installed within 6 ft (1.8 m)
of the dryer in accordance with the
National Fuel Gas Code, ANSI
Z223.1/NFPA 54.
-
Canada:
An individual manual shut off valve
must be installed in accordance
with the B149, Installation Codes,
CAN/CSA B149.1 and CAN/CSA
B149.2. It is recommended that an
individual manual shut off valve be
installed within 6 ft (1.8 m) of the
dryer.
5
4
3
1 1 1 1
1
1
/
" NPT gas supply line
2
2
Gas shut off valve
1
3
/
" NPT plugged tapping
8
3
4
/
" pipe to flare adapter fitting
8
3
5
/
" flexible gas connector (to the dryer)
8
The shut off valve should be easy to
reach for opening and closing.
Dryer gas pipe
The gas pipe that comes out through
the rear of the dryer has a
pipe thread.
Note:
The dryer must be checked for proper
operation whenever the gas
connections have been broken.
Connection of the dryer
d
CAUTION
Connection must be made by
a qualified technician.
The dryer must be disconnected
from the gas supply piping system
during pressure testing.